12
Note!
Control panel of welding machine is for function selection and some parameters setting. Welding
parameters can be adjusted by panel control (sub-menu parameter P09 is ON) and remote control
(sub-menu parameter P09 is OFF).
Fig. 4-3-1: Control panel
1.Adjustment knob
Adjust the parameters. When the light is on, this knob can be used to adjust parameters of selected item.
Reset
:Press adjustment knob (1) for about 5 seconds, it comes back to factory set.
Important!
Values increase in clockwise direction while values decrease in anti-clockwise rotation. To turn the knob left or
right while pressing it will achieve quick adjustment.
2. Parameters selection button F2
Press this button, one parameter indicator light is on, the corresponding parameter is chosen; keep pressing this button
can switch among the following parameters:
- Arc length adjustment
- Welding voltage
- Job (Channel) No.
If both the indicators of parameter selection button and the adjustment knob (1) are on, the indicated/ selected parameter
can be adjusted with the knob (1).
3.Parameters selection button F1
Press this button, one parameter indicator light is on and the corresponding parameter is chosen; keep pressing this
button can switch among the following parameters:
-
Welding current
-
Wire speed
-
Arc force/ Arc stiffness
Important!
On Panel control mode, press F1 to choose one of the above parameters, and value of the parameter can be
adjusted by the knob (1).
4. CALL button
Содержание AMIG-LST Series