background image

 

4

creating a shock hazard. If water enters the unit, unplug it immediately and contact 
Customer Service. It can result in the risk of electric shock. 

Use two or more people to lift and install the unit. Failure to do so can cause back injury 
or other injuries. 

 

         

CAUTION 

To reduce the risk of fire, electric shock, or injury to 

persons when using this appliance, follow basic precautions, including the 
following: 

To avoid possible cuts, avoid contacting the metal parts of the air conditioner when 
removing or reinstalling the filter. It can result in the risk of personal injury. 

Do not block the air inlet or outlet of the air conditioner. Reduced air flow will result in 
poor performance and could damage the unit. 

Always grasp the plug when plugging in or unplugging the air conditioner. Never unplug 
by pulling on the cord. It can result in the risk of electrical shock and damage. 

Always turn off and unplug the air conditioner when it will not be used for extended 
period of time. This conserves energy and reduces the chance of accidents. 

Secure the wheels with blocks to prevent the air conditioner from rolling on smooth 
floors. 

Install the air conditioner on a sturdy, level floor capable of supporting up to 110 lbs (50 
kg).

 

Installation on a weak or unlevel floor can result in the risk of property damage and 

personal injury. 

Make sure the air conditioner is the correct size for the area you wish to cool. Using an 
air conditioner that is the wrong size can waste energy and damage the air conditioner. 

Close all doors and windows to the room for most efficient operation. 

To prevent damage to the surface finish, use only a soft cloth to clean the air conditioner. 
Do not use wax, thinner, or a strong detergent. 

To prevent spills and property damage, be sure to drain the air conditioner properly. 

To prevent the coils from freezing, do not operate the air conditioner if the room 
temperature is below 62°F (17°C). 

Do not position the air conditioner so that pets or house plants are exposed to the direct 
air flow. It can result in the risk of injury to pets or house plants. 

This air conditioner is designed for normal household use. Do not use for cooling pets, 
foods, precision machinery, or art objects. 

Do not drink the water from the drain pan. Dispose of it properly outdoors or down the 
drain. 

Do not operate air conditioner without the filter securely in place. Operation without the 
filter could damage the unit. 

Clean the filter every two weeks, or more often if needed. 

 
 
 
 
 

Содержание AP11000

Страница 1: ...Portable Air Conditioner User Manual AP11000 Thank you for selecting this super quality air conditioner Please be sure to read this manual carefully before using it...

Страница 2: ...2 CONTENTS CONTENTS 2 IMPORTANT SAFETY INSTRUCTIONS 3 5 INSTALLATION 6 PART NAME 7 8 CONTROL PANEL 9 REMOTE CONTROL 10 OPERATION METHODS 11 WATER DRAINAGE 12 MAINTENANCE 12 TROUBLESHOOTING 13...

Страница 3: ...air conditioner before use It can result in personal injury Do not disassemble or modify the air conditioner or the power cord It can result in the risk of electric shock or fire Do not place the powe...

Страница 4: ...l the air conditioner on a sturdy level floor capable of supporting up to 110 lbs 50 kg Installation on a weak or unlevel floor can result in the risk of property damage and personal injury Make sure...

Страница 5: ...by a 15 amp time delay fuse or circuit breaker This air conditioner must be installed in accordance with national wiring codes Do not alter or modify the plug or cord of this air conditioner If the p...

Страница 6: ...und the unit Installation Fix the exhaust pipe into the adapter and then fix the other side of the exhaust pipe into the air outlet vent of the unit anti clockwise Fix the adapter into the window slid...

Страница 7: ...haust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause mal function BE CAREFUL Use the shortest pos...

Страница 8: ...g filter 13 Small filter 14 Draining hole Check all the accessories included in the package and please refer to the installation instructions for their usage Accessories Exhaust pipe Adapter Window sl...

Страница 9: ...tomatic time on when running time press this key to set automatic time off 5 UP button press this button to set the temperature higher when cooling press this button to adjust time longer when timing...

Страница 10: ...us and Fahrenheit exchange button 3 Fan button 4 Cool Mode Button 5 Auto mode button 6 Down button 7 Up button 8 High fan speed button 9 Low fan speed button 10 Max cool button 11 Sleep Mode 12 Timer...

Страница 11: ...en it is under automatic adjusting mode Sleep Mode Optional Function Press this button to activate or cancel sleep function in cooling mode The unit will run at the low fan speed as default with lower...

Страница 12: ...NTENANCE Note Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock Cleaning Unplug the unit before any cleaning Clean the housing with a soft moisture cloth...

Страница 13: ...hes on the display screen Drain water Timer off is running You can turn on the unit three minutes later The air conditioner restart frequently In direct sunlight Close curtains Windows or doors open m...

Отзывы: