IMPORTANT SAFETY INSTRUCTIONS

 

PLEASE  READ  ALL  INSTRUCTIONS  BEFORE  USING  THIS  APPLIANCE. 
Your safety and the safety of others is very important. 
 
BASIC SAFETY PRECAUTIONS 

           

WARNING

 

To reduce the risk of fire, electric shock, or injury to 

persons when using this appliance, follow basic precautions, including the 
following: 

Do not attempt to repair or replace any part of your air conditioner unless it is specifically 
in this manual. All other services should be referred to a qualified technician. 

If the power cord becomes worn or damaged, the cord should only be replaced by a 
qualified service technician using genuine replacement    parts. 

The air conditioner should be plugged into its own grounded 15A, 60 Hz., 120 VAC 
circuit. 

Do not plug other appliances into the same outlet; it can overload the circuit and cause a 
fire or electric shock. 

Do not remove the round grounding prong from the plug. It can result in the risk of 
electric shock. 

This air conditioner is not designed for use by young children. Young children should be 
supervised to ensure that they do not play with or climb on the air conditioner. 

Be sure all packaging materials are removed from the air conditioner before use. It can 
result in personal    injury. 

Do not disassemble or modify the air conditioner or the power cord. It can result in the 
risk of electric shock or fire. 

Do not place the power cord or air conditioner near a heater, radiator, or other heat 
source. It can result in the risk of electric shock or fire. 

Do not use this or any appliance near flammable gasoline, benzene, thinner, etc. It can 
result in the risk of electric shock or fire. 

Make sure the power cord is plugged firmly and completely into the outlet. It can result in 
the risk of electric shock or fire. 

Do not start or stop operation by plugging in or unplugging the power cord. It can result in 
the risk of electric shock. 

If the air conditioner is making unusual sounds or is emitting smoke or an unusual odor, 
unplug it immediately. It can result in the risk of electric shock or fire. 

Do not use if the electrical socket is loose or damaged. It can result in the risk of electric 
shock or fire. 

Do not operate with wet hands or in a damp environment. It can result in the risk of 
electric shock. 

Do not use this or any electrical appliance if you smell gas. It can result in the risk of fire 
or explosion. 

Turn off and unplug the air conditioner before cleaning to avoid the risk of electric shock. 

Do not clean the unit with water. Water can enter the unit and damage the insulation, 

Содержание AP11000

Страница 1: ...Portable Air Conditioner User Manual AP11000 Thank you for selecting this super quality air conditioner Please be sure to read this manual carefully before using it...

Страница 2: ...2 CONTENTS CONTENTS 2 IMPORTANT SAFETY INSTRUCTIONS 3 5 INSTALLATION 6 PART NAME 7 8 CONTROL PANEL 9 REMOTE CONTROL 10 OPERATION METHODS 11 WATER DRAINAGE 12 MAINTENANCE 12 TROUBLESHOOTING 13...

Страница 3: ...air conditioner before use It can result in personal injury Do not disassemble or modify the air conditioner or the power cord It can result in the risk of electric shock or fire Do not place the powe...

Страница 4: ...l the air conditioner on a sturdy level floor capable of supporting up to 110 lbs 50 kg Installation on a weak or unlevel floor can result in the risk of property damage and personal injury Make sure...

Страница 5: ...by a 15 amp time delay fuse or circuit breaker This air conditioner must be installed in accordance with national wiring codes Do not alter or modify the plug or cord of this air conditioner If the p...

Страница 6: ...und the unit Installation Fix the exhaust pipe into the adapter and then fix the other side of the exhaust pipe into the air outlet vent of the unit anti clockwise Fix the adapter into the window slid...

Страница 7: ...haust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause mal function BE CAREFUL Use the shortest pos...

Страница 8: ...g filter 13 Small filter 14 Draining hole Check all the accessories included in the package and please refer to the installation instructions for their usage Accessories Exhaust pipe Adapter Window sl...

Страница 9: ...tomatic time on when running time press this key to set automatic time off 5 UP button press this button to set the temperature higher when cooling press this button to adjust time longer when timing...

Страница 10: ...us and Fahrenheit exchange button 3 Fan button 4 Cool Mode Button 5 Auto mode button 6 Down button 7 Up button 8 High fan speed button 9 Low fan speed button 10 Max cool button 11 Sleep Mode 12 Timer...

Страница 11: ...en it is under automatic adjusting mode Sleep Mode Optional Function Press this button to activate or cancel sleep function in cooling mode The unit will run at the low fan speed as default with lower...

Страница 12: ...NTENANCE Note Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock Cleaning Unplug the unit before any cleaning Clean the housing with a soft moisture cloth...

Страница 13: ...hes on the display screen Drain water Timer off is running You can turn on the unit three minutes later The air conditioner restart frequently In direct sunlight Close curtains Windows or doors open m...

Отзывы: