39
INSTALLATION
Electrical connection
Warning!
All electrical work should be carried out by a
suitably qualified and authorised electrician.
No alterations or wilful changes in the electric
-
ity supply should be carried out.
The hob is manufactured to work with
a one-
-phase alternating current (230V 1N~50Hz)
and is equipped with a
3 x 1,5 mm
2
connec-
tion lead.
The electricity supply for the hob must have
a safety switch which enables the power to
be cut off in case of emergency. The distance
between the working contacts of the safety
switch must be at least 3 mm.
Before connecting the hob to the power sup
-
ply it is important to read the information on
the data plate and the connection diagram.
Caution! The installer is obliged to provide
the user with “appliance electrical connection
certificate” (enclosed with the warranty card).
Live L: BN - brown
Neutral N: BU - blue
Earth PE: GNYE -green/yellow
Power circuit should be protected with
a
16A
fuse.
Recommended type of connection lead:
H05VV-F, 3 x 1,5mm
2
.
Connection diagram
Caution! Voltage of heating elements 230V.
Caution! In the event of any connection the safety
wire must be connected to the
PE terminal.
GNYE
N
BU
BN
L
Important!
If the fixed power supply cable is damaged,
it should be replaced at the manufacturer
or at an authorized servicing outlet, or by a
qualified person to avoid danger.