INSTALLATION
Please make sure you have read and understood the entire operating manual. Do
follow the instructions to ensure safe and effective operation of your cooktop.
NOTE
The appliance uses gas, which is a flammable and explosive substance. Thus, it is
necessary for the cooktop to be connected to a gas network which supplies the gas
type for which the appliance is suitable.
Installation and service must be performed by a qualified installer, service agency
or gas supplier.
Please check the type plate for the information concerning the suitable gas type for
your appliance.
NOTE
The cooktops delivered by the supplier come with the burners which are suitable
for burning the type of gas which is quoted in the type plate and in the guarantee
certificate. The type plate is fitted at the bottom panel of the appliance. The following
must be carried out if converting to another gas type is required:
‑ nozzles must be replaced (see assembling table),
- reduced valve flow rate must be adjusted.
Converting the unit to another gas type
Only a licensed and authorised technician may carry out this job.
If the available gas type is different from that provided in the type plate of the appliance
2H
(G20/20 mbar)
, the burner nozzles should be replaced and flame adjusted.
Table 1
Converting the unit to another gas type
Gas type
Nozzle diameter
Small
Medium
Large
WOK
2H G20/20mbar
72
92
‑
52 + 2 x 75
3+ G30/28÷30/37mbar
52
67
‑
37 +2 x 55