15
The procedure for changing the gas type
Flame
Conversion from LPG
to natural gas
Conversion from natural
gas to LPG
full flame
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
2.Gently tighten the adju-
sting screw and check the
flame size.
Burner
small flame
hob
oven
full flame
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
O
C.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
the oven should be 150
O
C.
small flame
INSTALLATION
Surface burners
Type of gas
Burner
small
gas injector diameter
[mm]
medium
gas injector diameter
[mm]
large
gas injector diameter
[mm]
nominal thermal power
1,00 kW
nominal thermal power
1,80 kW
nominal thermal power
2,80 kW
G20 2H 20 mbar
0,72
0,98
1,17
G30/31 3+ 28-30 /37mbar
0,52
0,67
0,83
Oven burners
Type of gas
Oven Burner
top oven grill
gas injector diameter
[mm]
top oven
gas injector diameter
[mm]
main oven
gas injector diameter
[mm]
nominal thermal power
2,30 kW
nominal thermal power
2,10 kW
nominal thermal power
2,50 kW
G20 2H 20 mbar
1,15
1,10
1,15
G30/31 3+ 28-30 /37mbar
0,75
0,70
0,79