SAF 6000 910101-000107
07.2019
Page 18 of 28
The drive shaft housing and coarse screen:
Dismantling:
1. Close the inlet and outlet valves of the filter and release pressure.
2. Disconnect power supply from the control board.
3. Remove the cover (34) from the drive shaft housing (5) by unscrewing the wing nuts. Pull out the plug from the solenoid coil, remove
the limit switch sling (9 on page 24) from the drive shaft housing by unscrewing the bolts (14 on page 24).
4. Carefully put the limit switch sling near the filter to avoid any damage to the electrical wires.
5. Disconnect the pilot tube from the solenoid valve and connector.
6. Disconnect the drainpipe from the exhaust valve.
7. Remove the drive unit (28) from the drive shaft housing (5) by unscrewing the nuts from the bolts (29). By doing so, the drive shaft
key (27) will be pulled out.
8. Pull out the connecting pin (12) by first removing the split pin (13).
9. Turn the drive shaft (6 on page 24) using a suitable spanner in order to release it from the scanner shaft (2 on page 25).
10. Partially release the tightening nut (17 on page 24).
11. Dismantle the drive shaft housing (5) from the filter housing (1) by unscrewing the bolts (6).
12. Pull out the flushing chamber (3) and the coarse screen (2).
Assembly:
1. Insert the coarse screen (2) into its place in the filter housing.
2. Apply some grease on the O-ring and insert the flushing chamber into its place. Make sure the scanner pipe enters into its bearing.
3. Install the drive shaft housing (5) into the filter housing (1) with the bolts (6) and tighten them.
4. Connect the drive shaft (6 on page 24) to the scanner shaft by using the connecting pin (12) and split pin (13).
5. Make sure that the drive shaft key (27) is fitted properly in the gearbox. Thread the drive shaft through the drive unit and note that
the drive shaft groove is adjusted in accordance with the drive shaft key.
6. Connect the drive unit (28) to the drive shaft housing (5) with the bolts (29) and tighten them.
7. Connect the pilot tube between the solenoid valve (66) and the connector.
8. Assemble the limit switch sling in its place and push in the plug of the solenoid coil.
9. Connect the drainpipe to the exhaust valve.
10. Operate the control board and make sure the filter is operating properly.
11. Open the inlet and outlet valves and recheck filter operation.
Содержание SAF-6000
Страница 8: ...Dimensional Drawing ...
Страница 21: ...SAF 6000 910101 000107 07 2019 Page 21 of 28 Parts Drawing Section 1 ...
Страница 22: ...SAF 6000 910101 000107 07 2019 Page 22 of 28 Parts Drawing Section 1 Page 2 ...
Страница 24: ...SAF 6000 910101 000107 07 2019 Page 24 of 28 Parts Drawing Section 2 ...