the motor's full load amp rating. Replace the overload with the correct
overload module going from 460 to 230 system and re-wire the control
transformer and motor terminals inside the motor junction box. Do
not set or adjust to above full load amp rating.
Deadhead pressure cannot be met:
First determine if the pump motor is rotating in the correct direction.
Jog-start the motor control box hand switch off and on while observing
the motor shaft rotation.
If the pump is not rotating correctly, shut off the power and switch two
of the motor lead wires.
If the pump is rotating correctly, check for shut valves on the suction
line, a clogged suction line at inlet, a clogged strainer basket, or a
clogged pump.
Adjust the separator outlet valve to the required pressure drop across the
separator for the desired flow. If the flow rate cannot be obtained, check for
closed valves downstream of the separator, or restricted outlet piping.
Systems with Amiad Sweeper Jets, you can use the Sweeper Jets to act as a
control valve.
No solids in BGFS:
Purge valve to the inlet of the SRV is closed.
Air-locked in the system, bleed BGFS of trapped air. Follow BGFS
maintenance procedure.
Purge line is blocked. Isolate the system from pressure by closing the
purge line and liquid recovery line valves. Remove piping and clean
out the blockage or replace the appropriate components.
8 of 34
Содержание ICS-TCP Series
Страница 11: ...11 of 34 ...
Страница 12: ...12 of 34 ...
Страница 13: ...13 of 34 ...
Страница 14: ...14 of 34 ...
Страница 15: ...15 of 34 ...
Страница 16: ...16 of 34 ...
Страница 17: ...17 of 34 ...
Страница 18: ...18 of 34 ...
Страница 19: ...19 of 34 ...
Страница 22: ...Amiad USA INC Level I Filter Controller UL 508A Standard 22 of 34 ...
Страница 32: ...Page 11 Rev 091014 Operating and Maintenance Manual Page 11 32 of 34 ...