6” MCFM - 12000
01.2021
Page 33 of 61
LUBRICATION
Piston gear unit
All units are supplied with oil filling, oil level and drain plugs.
To fill the gear with oil remove the oil level and oil overflow plugs and fill through oil filling hole until lubricant overflows the oil level
plug hole.
Oil recommendation (0.85 liter capacity)
Esso
Spartan EP 320
Mobil Oil Co.
Mobil gear 632
Shell
Omala oil 320
Delek
Delphen EP 320
Moly Gear oil 300
Sonol
Compound 60
Paz
Pazamal 320
Optimol Optigear 5180
The units are supplied without oil. First oil change is recommended after 200 hours. Subsequent oil changes should be after 2000-
3000 hours according to working condition. Oil draining must be carried out while the oil is still warm, and after flushing the unit. For
long period storage, fill the unit completely with oil.
Change piston automatic greaser as suggested by the greaser manufacturer.
Grease O-rings and U-rings before re-using.
Add fluid to the absorber tank as required.
Add hydraulic oil to mist lubricators as required.
OEM Maintenance
OEM items include booster pump, various solenoid valves, automatic outlet valve, Delta P switches, various electronic items in the
controller, and electric motors. Maintenance of OEM items should be in accordance with OEM supplier recommendations.
Troubleshooting maintenance
Troubleshooting maintenance solutions are referred to in the PLC Controller Operation Manual.
Содержание Filtomat MCFM 12000
Страница 9: ...8 MCFM Page 10 of 61 P ID DRAWING 1 ...
Страница 16: ...6 MCFM 12000 01 2021 Page 17 of 61 Dimensional Drawing ...
Страница 20: ...6 MCFM 12000 01 2021 Page 31 of 61 Explosion Drawings ...
Страница 21: ...6 MCFM 12000 01 2021 Page 32 of 61 ...
Страница 27: ...8 MCFM 12000 06 2020 Page 61 of 61 ...
Страница 28: ...8 MCFM 12000 06 2020 Page 62 of 61 ...