Amiad Limited Warranty  

1.

 

This certificate applies to Amiad Water Systems Ltd. ("

Amiad

") products purchased by you (the "

Buyer

") from Amiad unless specifically 

agreed otherwise in writing by Amiad. This Warranty extends only to the original purchaser, and is not transferable to anyone who 
subsequently purchases, leases, or otherwise obtains the product from the original purchaser.  

2.

 

Amiad hereby warrants that the products are and will be free from defects in material and workmanship under normal use and service. 
Amiad warrants that it will correct manufacturing defects in the products, in accordance with the conditions set out in this Warranty. 

3.

 

This Warranty is enforceable for a period of 12 months after the date upon which the products were delivered (the “

Warranty Period

”). 

 

4.

 

In the event that during the Warranty Period the Buyer discovers a defect in material and/or workmanship in any product or part (the 

Defective Product

”), it shall submit a written complaint to Amiad using Amiad's standard Buyer Complaint Form. For the receipt of the 

Buyer Complaint Form, the submission of the complaint or any questions please contact your service representative.  

5.

 

Upon written demand by Amiad the Buyer shall return the Defective Product - or a sample thereof - to Amiad, at Amiad's cost. If the Buyer 
ships any such Defective Product, Amiad suggests the Buyer package it securely and insure it for value, as Amiad assumes no liability for 
any loss or damage occurring during shipment. Provided however that in the event Amiad determines that this Warranty does not apply to 
such product, Buyer shall promptly reimburse Amiad for such cost (including freight and customs). Any returned product or part must be 
accompanied by the Warranty certificate and the purchase invoice. It is clarified that the Buyer may not return the Defective Product 
unless such return was coordinated and approved by Amiad in advance.   

6.

 

Amiad's obligation under this Warranty shall be limited to, at Amiad's option, the repair or exchange, free of charge, of the product or any 
part which may prove defective under normal use and service during the Warranty Period. The provision of a repair or replacement of a 
product during the Warranty Period will result in an extension of the Warranty Period by an additional period of 12 months, provided that 
the total accumulated Warranty Period shall in any event be no more than 18 months from the date upon which the products were 
delivered.  

7.

 

This Warranty is valid on the condition that the products are installed according to Amiad's instructions as expressed in Amiad's instruction 
manuals and according to the technical limitations as stipulated in Amiad's literature or as stated by a representative of Amiad.  

8.

 

This Warranty will not apply to damaged or defective products resulting from or related to:  

(i)

 

Fire, flood, power surges or failures or any other catastrophe and/or unforeseen occurrence, such as but not limited to those for which 
the Buyer is customarily insured for, or any force majeure events;  

(ii)

 

Fault, abuse or negligence of the Buyer;  

(iii)

 

Intake water not meeting the agreed standards, as set forth in a written document, approved by Amiad, or improper storage;  

(iv)

 

Improper or unauthorized use of the product or related parts by the Buyer, including Buyer’s failure to operate the product i

conformity with the recommendations and instructions of Amiad, as set forth in Amiad's manuals and other written materials, the 
operation of the product other than by a trained and qualified operator, or improper installation of the product by a third party not 
authorized by Amiad;  

(v)

 

Performance by the Buyer of maintenance or operation other than in conformity with the recommendations and instructions of Amiad, 
or other than in accordance with procedures defined in the literature supplied for products (including the timely replacement of 
requisite parts), and for services provided other than by a trained and qualified advanced operator; or 

(vi)

 

Any alteration, modification, foreign attachment to or repair of the products, other than by Amiad or its authorized technical 
representatives.  

9.

 

In no event shall Amiad be liable to the Buyer or any third party for any damages to property, or for any intangible or economic loss, 
including loss of profits, loss of customers or damage to reputation, for any damages, including indirect, special, consequential damages, or 
punitive damage arising out of or in connection with this Warranty, or arising out of or in connection with the product's performance or 
failure to perform, even if it has been advised of the possibility of such damages.  

10.

 

Amiad will be excused for failure to perform or for delay in performance hereunder if such failure or delay is due to causes beyond its 
reasonable control or force majeure preventing or hindering performance. 

11.

 

This Warranty set forth herein is the only contractual warranty given by Amiad and is provided in lieu of any other warranties created by 
any documentation, packaging or otherwise.  

12.

 

Amiad makes no warranty whatsoever in respect to accessories or parts not supplied by Amiad. In the event that Amiad is required to 
correct a Defective Product or product not covered by this Warranty, it will do so solely in consideration for additional fees. 

13.

 

The parties will actively endeavor to amicably settle any dispute arising between them. In the event that the parties are unable to reach an 
equitable settlement of such dispute, any claim or lawsuit related to the Warranty, its validity execution, its performance be brought 
before only the courts of Tel-Aviv, Israel. Israeli law will govern the Warranty, to the exclusion of any conflict of law rules

   

 
 

Содержание EBS-15000 On-Line

Страница 1: ...AMIAD Water Systems EBS 15 000 On Line 16 20 Serial number Order number Catalog number Filtration degree Tested by Installation Operation and Maintenance Instructions Ref 910101 000111 08 2019 ...

Страница 2: ...t or its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes th...

Страница 3: ...DEGREES AVAILABLE 4 SAFETY INSTRUCTIONS 5 GENERAL SAFETY INSTRUCTIONS 5 INSTALLATION 5 COMMISSIONING 6 OPERATION AND CONTROL 6 MAINTENANCE 7 DISMANTLING ASSEMBLING OF FILTER COMPONENTS 14 PARTS LIST EBS 15000 ON LINE 17 PARTS DRAWING 1 18 PARTS DRAWING 2 19 PARTS DRAWING 3 20 AMIAD LIMITED WARRANTY 21 With any inquiry please quote Filter Serial Number located on the filter housing ...

Страница 4: ...me 36 seconds Wasted water per cycle 500liter 132USgal at 2bar 30psi Minimum flow for flushing 50m3 h 220USgpm at 2bar 30psi Control and electricity Electric motor 1 2 HP 50 60 Hz 20 24 Gear output R P M Rated operation voltage 3 phase 220 480 V 50 60 Hz Single phase 110 220 V 50 60 Hz Control voltage 24V AC 12V or 24V DC upon request Current consumption 1 5 Amp with 3 phase 380V 440V Construction...

Страница 5: ...ble lighting at the area of the filter to enable good visibility and safe maintenance The user should arrange suitable platforms ladders and safety barriers to enable easy and safe access to the filter without climbing on pipes and other equipment The user should verify that any platform barrier ladder or other such equipment is built installed and used in accordance with the relevant local author...

Страница 6: ...t Please note that the maximum working pressure indicated at the filter s specifications table includes the pressure caused by fluid hammer and pressure surge effects Civil Engineering Make sure that the filter installation is done by Amiad qualified technicians Make sure that any civil engineering work at the installation site such as construction lifting welding etc is done by qualified workers ...

Страница 7: ...o minimize slippage electrification or damage to the equipment caused by moisture While using lifting equipment make sure that the filter or the lifted part is chained securely and in a safe manner Do not leave lifted equipment if there is no necessity Avoid working below lifted equipment Wear a safety helmet goggles gloves and any other personal safety equipment required by the local standards an...

Страница 8: ...EBS 15000 OL 910101 000111 910101 000111 08 2019 Page 8 of 22 DIMENSIONAL DRAWING RECOMMENDED INSTALLATION This is a conceptual installation drawing Note that piping is not included ...

Страница 9: ...the HMI 4 Malfunction mode During malfunction mode the self cleaning operation is stopped the malfunction light on the control board is turned on and an external output is activated In case that there is HMI the relevant fault error will be displayed The filtration system may enter a malfunction mode in the following cases 1st When there is a continuous signal from the pressure differential switch...

Страница 10: ...ctions 2 Select a convenient location for the installation of the filter where operation and maintenance will be optimal It is recommended that a standard and safe lifting auxiliary is available for maintenance 3 Install the filter vertically Please note that a minimum clearance of 300 mm 12 In Not including a crane is required in order to allow disassembly of the unit 4 Ensure that the direction ...

Страница 11: ...awings 3 Verify by authorized electrician only that the electric wiring is correct and complies with the enclosed drawings Make sure that the electrical start up operation is done by an authorized electrician only 4 Switch ON the control 24V circuit breakers Leave the motor OL circuit breaker protector OFF 5 Toggle all limit switches to verify that they activate the correct inputs on the PLC accor...

Страница 12: ...it is necessary add grease to the filter s suction scanner shaft 5 Take care of any leakage from the scanner shaft If necessary replace the Sealing flange Internal O Ring 5 on page 23 as described at the following list 6 Reconnect the filter carefully and safely to its water air and power supply 7 Perform a General Inspection of the Filter Operation as described above Changing the sealing flange i...

Страница 13: ...lly for a Proper operation b Any leakage from the filter housing or accessories c Abnormal or unusual noises d Loosen bolts e Non smooth turning of the suction scanner f Unusual load on the filter electrical motor g Any sign of corrosion on the filter housing or accessories h Unusual vibrations i Non smooth operation of the filter valves air release valves and check valves 2 Close the inlet and th...

Страница 14: ...well If the connecting pin is not facing one of the shaft housing windows turn the drive shaft 11 a little Use 17mm or 11 16 spanners 7 Turn the drive shaft 11 counter clockwise so that it will be separated from the suction scanner shaft 7 3 8 Unscrew bolts 29 2 and remove the limit switches sling without disconnecting and changing the limit switches position 9 Unscrew bolts 10 5 connecting shaft ...

Страница 15: ...xtractor 2 Fold the Extractor upwards Figure 1 Figure 1 3 Insert the Extractor into the screen about a quarter from top Make sure that the extractor cushions do not touch the stitch found along the screen interior 4 Pull the extractor up so that it is firmly set against the inside wall of the Screen Figure 2 Figure 2 5 Attach a lifting device to the ring on the Extractor and extract Never lift the...

Страница 16: ...er the shaft housing 22 Place the bolts 10 5 but do not yet tighten them firmly 9 Turn the drive shaft 11 clockwise until it reaches the suction scanner shaft Insert the connecting pin 20 1 to the hole in the drive shaft through the suction scanner shaft hole 10 Insert the split pin 20 2 in its original position 11 Make sure that the drive shaft key 11 1 is in its place Apply grease on it and reas...

Страница 17: ...24X92 NBR 770103 000046 15 DRIVE SHAFT COVER EBS 15K RED 710105 001783 15 1 HEX NUT M6 S ST316 DIN934 760102 000085 16 BALL VALVE 3 4 M F BRASS NI 730104 000220 No Description Cat No 16 1 L CONNECTOR 3 4 F M GALVANIZED 780101 000789 17 3 4 BSPT AC BLACK SCREEN 200 M 010000 000042 17 1 O RING SEAL P2 112 NBR S 770102 000082 17 2 RACCORD NIPPLE 1 4 FOR 3 4 FILTER 710103 002569 17 3 RACCORD NUT 3 4 F...

Страница 18: ...EBS 15000 OL 910101 000111 910101 000111 08 2019 Page 18 of 22 PARTS DRAWING 1 ...

Страница 19: ...EBS 15000 OL 910101 000111 910101 000111 08 2019 Page 19 of 22 PARTS DRAWING 2 ...

Страница 20: ...EBS 15000 OL 910101 000111 910101 000111 08 2019 Page 20 of 22 PARTS DRAWING 3 ...

Страница 21: ...a representative of Amiad 8 This Warranty will not apply to damaged or defective products resulting from or related to i Fire flood power surges or failures or any other catastrophe and or unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events ii Fault abuse or negligence of the Buyer iii Intake water not meeting the agreed...

Страница 22: ...ter Systems Ltd D N Galil Elyon 1 1233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration https www amiad com certificatesDownload asp ...