 Filter Installation 

 

 

 

 

 

 

 

 

 

 

 

Before lifting this unit we recommend a full risk assesment be conducted, taking into account the balance on 

the unit and potential stress and damage, which may be caused to pipework by unsupported lifting. 

 

Place the filter in its final position ensuring the location is stable, level and suitable for the support of the 

system’s operational weight. Installers should ensure suitable access is available to dismantle top flange of 

the unit to carry out any media loading or maintenance that may be necessary. Check this by removing and 

refitting top flange. (Filter is pre-loaded with media prior to dispatch). 

 

Check for all round access allowing at least 1m in all directions for  ease of access. In restricted locations 

please refer to factory before fixing in place in any  areas that are  adjacent  to fixed objects. Once these 

criteria are satisfied, secure the filter down. 

 

The filter may be located inside or outside, but if an outside location is chosen, care should be taken that the 

filter is not subjected to ambient temperatures of below +2

°

C without heat tracing. If there is any risk of this, 

you should consult with Amiad Water Systems. 

 

Connect  inlet/outlet process pipe-work,  backwash and drain to the  unit as  necessary and check all filter 

connections for tightness,  as  fittings may  become  loose during transit.  Remember  not to overtighten the 

connections. 

 

If the control panel doesn’t come pre-mounted, mount it adjacent to the filter unit. The control panel should 

be located so as not to come into direct or sustained contact with water. The panel has an IP rating of IP65. 

 

Client Scope of Supply  

 

 

 

 

 

 

 

 

 

An incoming electrical supply suitable for a control panel. 

 

A suitable pipe-work for connecting the filter via V1, V2, V3, V4. 

 

Note that pipe-work interface V4 must allow a flow under gravity without any obstructions (2-10m max). 

 

A gate valve on the outlet pipe-work to adjust the process flow (Downstream V2). 

 

A gate valve on the drain pipe-work to adjust the backwash flow (Downstream V4). 

 

An isolation valve on the inlet & outlet process supply is recommended as good engineering practice. 

 

A by-pass to allow for filter maintenance offline is a good engineering practice and strongly recommended. 

 

All pipe-work should be fully supported to ensure no undue mechanical stress is placed on the filter. 

 

 

Содержание DVF

Страница 1: ...iltration System Serial Numbers _____________________ Order number _____________________ Catalog number _____________________ Filtration degree _____________________ Year _____________________ Installation Operation and Maintenance Instructions December 2019 Original Instructions 910101 001048 ...

Страница 2: ...its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that al...

Страница 3: ...First Operation 17 3 Periodic Iinspection 17 4 Monthly Maintenance 17 5 Yearly Maintenance 18 6 Replacing the filter media 18 Parts Maintenance 19 1 Filter Vessel 19 2 Filter Media PEP ACTIVE Activated Filter Media 19 DVF 300 Filter GA Drawing 21 DVF 300 Filter Parts Drawings 22 DVF 300 Filter Parts List 23 DVF 600 Filter GA Drawing 24 DVF 600 Filter Parts Drawings 25 DVF 600 Filter Parts List 23 ...

Страница 4: ...scharging wastewater to drain it is the responsibility of the user to determine the legal discharge route for contaminated water from the filter Electrical connections should be done in accordance with national standards and carried out by competent persons only Amiad filtration products always operate as components in a larger system It is essential for the system designers installers and operato...

Страница 5: ...ce with the relevant standards and regulations For shipping lifting and positioning the filter use only approved lifting equipment authorized employees and contractors Pneumatics Ensure that the compressed air supplied to the filter never exceeds the maximum designated pressure for the filter An air pressure reduction valve should be installed on the compressed air supply line upstream of the filt...

Страница 6: ... use the filter for purposes other than its original design and operational envelope 4 Maintenance Servicing the filter should be performed by an authorized manufacturer s technician only Before any maintenance or non regular operation carefully read the following Disconnect the filter from the power supply and lock the main power switch Disconnect any compressed air supply release the residual pr...

Страница 7: ...h water pressure or steam should be performed in accordance with cleaning system instructions local standards and regulations and without endangering the operator or the vicinity Before returning to regular operation Re assemble any protective covers or protection mechanisms removed during service or maintenance operations Ensure that all the tools ladders lifting devices etc used during the maint...

Страница 8: ...N10 Flanged Process Water Outlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Backwash Inlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Backwash Outlet Connection 1 DN 25 ISOPN10 Flanged 1 DN 40 ISOPN10 Flanged 2 DN 50 ISOPN10 Flanged 3 DN 80 ISOPN10 Flanged Minimum Operati...

Страница 9: ...s supplied with multi level graded glass The backwash period is adjustable depending on the nature of the contamination being removed Filter Configuration The DVFis a patented filter system for water which can remove particulate down to 1 micron nominal in size Each unit has a total of four valve connections namely Process Inlet Valve V1 This is the filter s inlet connection for the dirty process ...

Страница 10: ... continues on line filtration until backwash is initiated This is usually done via a pressure differential switch supplied as part of the control package a timer adjustable through the controller or manually by pressing the backwash button Once backwash is triggered by either of the above V1 and V2 close the filter will no longer be producing any process water until the backwash cycle is complete ...

Страница 11: ... the vessel air inlet If the airline is relatively long calculate the dynamic head loss and take it in to account An air valve MUST be installed to handle the blower air flow with the minimal hydraulic resistance ARI D070P model is recommended A vacuum breaker MUST be installed on the drain line Process Description Partial Draining This stage is designed to enable room on the upper part of the ves...

Страница 12: ...he filter and run the BW cycle DVF Scouring Design Table DVF Model Scouring Pressure Bar Scouring Velocity m hr Vessel Diameter m Vessel Area m Nominal Operation Flow m h DVF 300 0 5 0 6 70 0 3 0 07 5 DVF 600 0 5 0 6 70 0 6 0 28 20 DVF 900 0 5 0 6 70 0 9 0 64 45 DVF 1200 0 5 0 6 70 1 2 1 13 79 ...

Страница 13: ...nt temperatures of below 2 C without heat tracing If there is any risk of this you should consult with Amiad Water Systems Connect inlet outlet process pipe work backwash and drain to the unit as necessary and check all filter connections for tightness as fittings may become loose during transit Remember not to overtighten the connections If the control panel doesn t come pre mounted mount it adja...

Страница 14: ... to the differential pressure switch Electrical Connections Electric wiring must be performed by an authorized electrician only using standardized and approved components Install a lockable main power cut off switch close to the control panel If due to site constraints the control panel is installed without a clear line of vision to the filter an additional lockable power disconnect cut off switch...

Страница 15: ... use correct PPE during media installation See media data sheets which can be found on the bags and further in this document o First ensure that the valves on the backwash inlet V3 and process outlet V2 are closed o Now via the top flange fill half the vessel with clean fresh water This is to ensure no damage occurs to the backwash nozzles located within the vessel base o Load the base media in th...

Страница 16: ...e 1 Depth mm 181 212 251 212 Weight kg 16 75 200 300 of Bags 3 Bags 8 Bags 12 Bags Grade 2 Depth mm 219 200 287 305 Weight kg 19 75 225 425 of Bags 3 Bags 9 Bags 17 Bags Grade 3 Depth mm 232 218 161 210 Weight kg 20 75 125 290 of Bags 3 Bags 5 Bags 12 Bags Total Bed Weight kg 85 350 800 1465 Total Bed Height mm 951 978 996 1025 Media configurations can vary according to process ...

Страница 17: ...Flush the filter until the backwash outlet V4 water is clean Note Ensure minimal backwash flowrate according to the technical data table pp 8 3 Switch to Auto operation mode 4 Adjust all operational setpoints in the control system as per control philosophy Recommendations clean DP 0 3 bar Backwash trigger DP 0 8 bar 3 Periodic Inspection 1 Check for leaks from connections and fittings If leaks are...

Страница 18: ...lter media through the service hole on the side of the filter Thoroughly clean the inside of the filter with clean water Inspect the filter mushrooms and the double bottom Carefully close the service covers on the side Fill the filter media through the filling hole top lid and continue to follow the instructions in the section Media Filling Process 6 Replacing the filter media 1 Replace the filter...

Страница 19: ...spect condition of securing bolts replace as required 2 Filter Media PEP ACTIVE Activated Filter Media Weekly Maintenance Check and log differential pressure Monthly Maintenance Perform a manual backwash cycle and visually inspect drain for media carry Yearly Maintenance Removal of upper hatches for media inspection Perform a media sanitation disinfection if required solution of hypochlorite 5 Top...

Страница 20: ...910101 001048 12 2019 Page 20 of 42 DVF Filter P ID Drawing ...

Страница 21: ...910101 001048 12 2019 Page 21 of 42 DVF 300 Filter GA Drawing ...

Страница 22: ...910101 001048 12 2019 Page 22 of 42 DVF 300 Filter Parts Drawing ...

Страница 23: ...WITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 6 770103 000471 GASKET 1 ISO PN10 EPDM DN25 TH2MM FULL FACE 4 EPDM 7 730104 000573 2 WAY BALL VALVE 1 ISO10 2528 S ST ELECTRIC HQ 004 DN25 GENEBRE ACT SOL 4 Various 7 730104 000573 2 WAY BALL VALVE 1 ISO10 2528 S ST ELECTRIC HQ 004 DN25 GENEBRE ACT SOL 4 Various 7 1 730104 000572 2 WAY BALL VALVE 1 ISO10 2528 S ST W O ACTUA...

Страница 24: ...910101 001048 12 2019 Page 24 of 42 DVF 600 Filter GA Drawing ...

Страница 25: ...910101 001048 12 2019 Page 25 of 42 DVF 600 Filter Parts Drawing ...

Страница 26: ... 316 5 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 6 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 7 730104 000574 2 WAY BALL VALVE 1 1 2 ISO10 2528 S ST ELECTRIC HQ 004 DN40 GENEBRE ACT SOL 4 VARIOUS 7 1 730104 000575 2 WAY BALL VALVE 1 1 2 ISO10 2528 S ST W O ACTUATOR DN40 GENEBRE 4 S ST 304 7 2 720701 00...

Страница 27: ...910101 001048 12 2019 Page 27 of 42 DVF 900 Filter GA Drawing ...

Страница 28: ...910101 001048 12 2019 Page 28 of 42 DVF 900 Filter Parts Drawing ...

Страница 29: ...T316 1 4 BSP BOTTOM 2 W GLYCERINE 2 S ST 316 6 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 7 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 8 730104 000577 2 WAY BALL VALVE 2 ISO10 2528 S ST ELECTRIC HQ 004 DN50 GENEBRE ACT SOL 4 VARIOUS 8 1 730104 000576 2 WAY BALL VALVE 2 ISO10 2528 S ST W O ACTUATOR DN50 ...

Страница 30: ...910101 001048 12 2019 Page 30 of 42 DVF 1200 Filter GA Drawing ...

Страница 31: ...910101 001048 12 2019 Page 31 of 42 DVF 1200 Filter Parts Drawing ...

Страница 32: ...ST316 1 4 BSP BOTTOM 2 W GLYCERINE 2 S ST 316 6 720101 000776 FLUSHING CONTROLLER TECNOLOGIC 5REL S240VAC AC 5 BESPOKE FOR DVF 1 Various 7 720104 000025 DP SWITCH W BRACKET BACCARA 1 8 BSPM REAR 14BAR 0 5BAR IP66 12794121 1 Various 8 730104 000579 2 WAY BALL VALVE 3 ISO10 2528 S ST ELECTRIC HQ 008 DN80 GENEBRE ACT SOL 4 VARIOUS 8 1 730104 000578 2 WAY BALL VALVE 3 ISO10 2528 S ST W O ACTUATOR DN80...

Страница 33: ...leshooting Flowchart The majority of faults and problems are associated with the installation rather than the filter system itself Here is a flow chart of the most common faults in order that you may check them before calling our service technicians ...

Страница 34: ...ve of Amiad 8 This Warranty will not apply to damaged or defective products resulting from or related to i Fire flood power surges or failures or any other catastrophe and or unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events ii Fault abuse or negligence of the Buyer iii Intake water not meeting the agreed standards as ...

Страница 35: ...910101 001048 12 2019 Page 35 of 42 Annex A Media Safety Data Sheet 7 pages ...

Страница 36: ...910101 001048 12 2019 Page 36 of 42 ...

Страница 37: ...910101 001048 12 2019 Page 37 of 42 ...

Страница 38: ...910101 001048 12 2019 Page 38 of 42 ...

Страница 39: ...910101 001048 12 2019 Page 39 of 42 ...

Страница 40: ...910101 001048 12 2019 Page 40 of 42 ...

Страница 41: ...910101 001048 12 2019 Page 41 of 42 ...

Страница 42: ...r the CE marking in conformity with the art 4 par 3 Pressure Equipment Directive 2014 68 EU Manufacturer Amiad Water Systems Ltd D N Galil Elyon 1 1233500 Israel Tel 972 4 690 9500 Fax 972 4 814 1159 Email info amiad com EC Representative for CE Matters Obelis S A Boulevard Général Wahis 53 B 1030 Brussels BELGIUM Email info obelis com ...

Отзывы: