11
TABLE 2 - BMF Connections
(All in inches)
Filter
Model
Filter Inlet
Filter Outlet Backwash
Pump Inlet
(Optional)
Pre-strainer
BMF-54
4
4
4
3
4
BMF-60
4
4
4
3
4
BMF-66
4
4
4
5
5
BMF-72
6
6
6
5
5
BMF-78
6
6
6
5
5
BMF-84
6
6
6
5
6
BMF-90
6
6
6
6
6
BMF-96
8
8
8
6
6
TABLE 3 - BMF Flow Rates
Filter
Model
Filtration Flow
Rate
GPM / LPS
Backwash
Minimum
GPM /LPS
Backwash
Maximum
GPM / LPS
BMF-54
318 / 20.1
239 / 15
318 / 20.1
BMF-60
393 / 24.8
294 / 18.6
393 / 24.8
BMF-66
475 / 30
357 / 22.5
475 / 30
BMF-72
566 / 35.7
425 / 26.8
566 / 35.7
BMF-78
663 / 41.8
498 / 31.4
663 / 41.8
BMF-84
770 / 48.6
578 / 36.5
770 / 48.6
BMF-90
884 / 55.7
663 / 41.8
884 / 55.7
BMF-96
1006 /63.4
756 / 47.7
1006 / 63.4
TABLE 4A - BMF Electrical Requirements, 60 Hz
Filter Model
Pump
HP / KW
Voltage (3 phase)
60 HZ
Full Load Current
(Amps)
BMF-54
7.5 / 5.6
208, 230, 460, 575
24.2, 22, 11, 9
BMF-60, 66, 72 10 / 7.5
208, 230, 460, 575
30.8, 28, 14, 11
BMF-78, 84, 90 15 / 11.2
208, 230, 460, 575
46.2, 42, 21, 17
BMF-96
20 / 15
208, 230, 460, 575
59.4, 54, 27, 22
TABLE 4B - BMF Electrical Requirements, 50 Hz
Filter Model
Pump
HP / KW
Voltage (3 phase)
50 HZ
Full Load Current
Amps
BMF-54
7.5 / 5.6
380, 415
11.5, 10.6
BMF-60, 66, 72 10 / 7.5
380, 415
15.1, 13.5
BMF-78, 84, 90 15 / 11.2
380, 415
23.7, 22.4
BMF-96
20 / 15
380, 415
31.1, 29.2
Содержание BMF Series
Страница 17: ...Rev 10 2017 BMF Pre Engineered Skid IOM 17 PUMP CURVES ...
Страница 18: ...Rev 10 2017 BMF Pre Engineered Skid IOM 18 ...
Страница 19: ...Rev 10 2017 BMF Pre Engineered Skid IOM 19 ...
Страница 20: ...Rev 10 2017 BMF Pre Engineered Skid IOM 20 ...
Страница 21: ...Rev 10 2017 BMF Pre Engineered Skid IOM 21 ...
Страница 22: ...Rev 10 2017 BMF Pre Engineered Skid IOM 22 ...
Страница 23: ...Rev 10 2017 BMF Pre Engineered Skid IOM 23 ...
Страница 24: ...Rev 10 2017 BMF Pre Engineered Skid IOM 24 ...
Страница 34: ...Rev 10 2017 BMF Pre Engineered Skid IOM 34 Appendix 1 Pump IOM ...
Страница 35: ...INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ELECTRIC MOTORS Frames 143 5T 586 7T ...