36
V
.
TEST RUN
1. Preparation before Synchronous adjustment
a. Fill the reservoir with hydraulic oil. In consideration of power unit’s durability and
keep the equipment running in the perfect condition,
please use Hydraulic Oil
46#.
b. Turn on the power after connecting oil system correctly. Press the button
Up
, and
check the rotated direction of the motor (This is right if lift is upward, otherwise, it is
wrong direction of the motor). Shut off power and exchange the phase connection if
the direction is wrong.
c. Lower the platforms to the lowest position.
2. Synchronous adjustment
a. Turn the handles of the shutoff valves to the position as
Fig. 45
(Normal working
position), push
UP
button to start filling oil in the cylinder, until the machine starts to lift.
at this time push
Down
and
Pass
button about 5 seconds while hearing the buzzer
sound and the sounds of inside air coming out from oil tank . Repeat the above steps
2-3 times until the inside air are all come out.
b. Tap
UP
button, until the platform just be lifted up.
c, Turn the handle of shutoff valves to the position as
Fig.46.
push
UP
button, check If
PI ,PII platform at the same time means the machine is synchronization. If still not,
repeat b steps until the both side of platform are synchronization.
d, After PI,PI platform are synchronization, operating the lift up and down.
3. Test run
Check and adjust the limit switch, the hose and fitting connection, and do test run.
The lift must be tested run and checked carefully before in use.
Fig. 45
Fig. 46
Normal Working Position
Oil Filling Position
Содержание AX-12
Страница 1: ...1 SCISSORS LIFT Model AX 12A AX 12 Original...
Страница 13: ...11 4 2 Parts bag for flush mount installation See Fig 19 Fig 20 For AX 12A For AX 12 Fig 19 Fig 20...
Страница 28: ...26 MODEL AX 12 Fig 39...
Страница 32: ...30 CYLINDERS Fig 40 Add grease to lubricate regularly Add grease to lubricate regularly...
Страница 34: ...32 CONTROL CABINET 73 76 82 71 80 81 Fig 41...