AMG5904A966B9 Instruction Sheet
D22153-00.doc

be accessed by removing the 2 fixing screws in the rear panel and sliding the PCB out of the
enclosure.

For clarity, in the 3 examples shown below all 4 data ports D1-D4 are terminated the same, but each
data channel may be configured & terminated independently as required. The 3 examples shown are

RS-232 (no termination), RS-422 (120Ω) or RS-485 (120Ω). 

Alarm Channel Configuration

The

AMG5904A966B9

provides 8 bi-directional contact closure inputs / alarm outputs. Each ALARM

IN input is via an internal 10kΩ series resistor with a 47kΩ pull-up resistor to the in3V3 supply. 

Each ALARM OUT output can receive an on/off signal from an

AMG5903A966B9

and is typically used

to convey contact closure status. Each alarm output is NPN open collector, maximum load 500mA /
24Vdc.

Alarm Channel Circuit

The output of each alarm channel is an NPN open collector transistor circuit, with an absolute
maximum rating of 1A / 60V. There is a common GND for all alarm channels.

Содержание AMG5904A966B9

Страница 1: ...els and 8 Bi directional Alarms plus Ethernet for a Singlemode Fibre Link The AMG5904A966B9 is a standalone data receive unit designed to transmit and receive 2 data channels 14 audio channels 2 Echel...

Страница 2: ...4 Echelon FTT 10A Data Channel Connection 5 Ethernet Connection 5 Front Panel Indicators 6 Power LED 6 Low Speed Data LEDs 6 Audio LEDs 6 Alarm LEDs 7 Echelon FTT 10A Data LEDs 7 Ethernet Data LEDs 7...

Страница 3: ...5904A966B9 transmits and receives 2 data channels 2 Echelon FTT 10A data channels 14 bi directional audio signals and 8 bi directional alarm signals to from the AMG5903A966B9G transmit unit Ethernet c...

Страница 4: ...s Phoenix 1952296 Data Interfaces RS 232 422 485 Selected by external slide switches D1 D2 RS 232 Switch Position Top RS 422 Switch Position Middle RS 485 Switch Position Bottom Internal 120 terminati...

Страница 5: ...struction Sheet D22153 00 doc Echelon FTT 10A Data Channel Connection No of Echelon FTT 10A Data Channels 2 Echelon FTT 10A BANK A Channels 7 and 8 Echelon FTT 10A BANK B None Connector 37 way D Type...

Страница 6: ...ransitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V pres...

Страница 7: ...nto the optical fibre Data Present OUT Green Data channel present but not transmitting R G Data channel receiving Off Data channel not present or no connection OUT corresponds to the data signals bein...

Страница 8: ...A level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively It is important therefore to terminate the RS 485 bus or the RS 422 input bus using 120 if a pre bias is...

Страница 9: ...ently as required The 3 examples shown are RS 232 no termination RS 422 120 or RS 485 120 Alarm Channel Configuration The AMG5904A966B9 provides 8 bi directional contact closure inputs alarm outputs E...

Страница 10: ...6 IN ALARM 2 6 OUT 3 GND GND 4 ALARM 3 7 IN ALARM 3 7 OUT 5 ALARM 4 8 IN ALARM 4 8 OUT Audio Channel Configuration The AMG5904A966B9 provides fourteen bi directional audio channels Each audio channel...

Страница 11: ...A B 5 Audio CH3 IN A B 24 Audio CH3 OUT A B 6 Audio CH3 IN A B 25 Audio CH3 OUT A B 7 Audio CH4 IN A B 26 Audio CH4 OUT A B 8 Audio CH4 IN A B 27 Audio CH4 OUT A B 9 GND A B 28 GND A B 10 GND A B 29...

Страница 12: ...tems in accordance with EN 60825 2 2000 It is always advisable to follow good practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved c...

Отзывы: