![AMG AMG5904A966B9 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/amg/amg5904a966b9/amg5904a966b9_instruction-manual_2931942007.webp)
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 7 of 12
AMG5904A966B9 Instruction Sheet
D22153-00.doc
Alarm LEDs
Channels 1-8
ALARM IN............................................ Green
-
Alarm ON / Contacts closed.
Off
-
Alarm OFF / Contacts open.
ALARM OUT........................................ Green
-
Alarm ON / Contacts closed.
Off
-
Alarm OFF / Contacts open.
Echelon FTT-10A Data LEDs
Data type depends on AMG system: RS-232, RS-422, RS-485, 20mA,TTL, or FTT-10A
Data Present IN .................................. Green
-
Data channel present but not transmitting
R/G
-
Data channel transmitting
Off
-
Data channel not present or no connection
IN corresponds to the data signals being transmitted onto the optical fibre.
Data Present OUT ............................... Green
-
Data channel present but not transmitting
R/G
-
Data channel receiving
Off
-
Data channel not present or no connection
OUT corresponds to the data signals being received from the optical fibre.
Ethernet Data LEDs
Link not Present .................................. Yellow
-
Link not present
Off
-
Link is present
Link Integrity ........................................ Green
-
Link integrity is good, Idle state
GBlink -
Data transfer
Off
-
Link not present
Ethernet Operation
The Ethernet interface supports 100Mbit/s full duplex operation only. Data is transmitted from one port
the other port with minimum delay or buffering.
The port implements "Auto MDI/MDIX" i.e. it may be connected with either a straight-though or cross-
over cable to an appropriate device such as external switch, PC or other DCE/DTE.
Two LED indicators are provided adjacent to the RJ-45 port: Green indicates Link / Data transfer and
Yellow indicates no Ethernet connection.