AMG5904A966B9 Instruction Sheet
D22153-00.doc

AMG5904A966B9

Instruction Manual

Data Receive Unit with 2 Bi-directional Data Channels, 14

Bi-directional Audio Channels, 2 Echelon FTT-10A Data

Channels and 8 Bi-directional Alarms plus Ethernet for a

Singlemode Fibre Link

The

AMG5904A966B9

is a standalone data receive unit designed to transmit and receive 2 data

channels, 14 audio channels, 2 Echelon FTT-10A data channels and 8 bi-directional alarms over one
Singlemode optical fibre. It also provides full duplex 100BASE-TX Ethernet connectivity.

The

AMG5904A966B9

is designed to be powered using an

AMG2003

standalone power supply.

The

AMG5904A966B9

is designed to operate with an

AMG5903A966B9

standalone or

AMG5903A966B9G

rackmount data transmit unit in a point to point configuration.

Содержание AMG5904A966B9

Страница 1: ...els and 8 Bi directional Alarms plus Ethernet for a Singlemode Fibre Link The AMG5904A966B9 is a standalone data receive unit designed to transmit and receive 2 data channels 14 audio channels 2 Echel...

Страница 2: ...4 Echelon FTT 10A Data Channel Connection 5 Ethernet Connection 5 Front Panel Indicators 6 Power LED 6 Low Speed Data LEDs 6 Audio LEDs 6 Alarm LEDs 7 Echelon FTT 10A Data LEDs 7 Ethernet Data LEDs 7...

Страница 3: ...5904A966B9 transmits and receives 2 data channels 2 Echelon FTT 10A data channels 14 bi directional audio signals and 8 bi directional alarm signals to from the AMG5903A966B9G transmit unit Ethernet c...

Страница 4: ...s Phoenix 1952296 Data Interfaces RS 232 422 485 Selected by external slide switches D1 D2 RS 232 Switch Position Top RS 422 Switch Position Middle RS 485 Switch Position Bottom Internal 120 terminati...

Страница 5: ...struction Sheet D22153 00 doc Echelon FTT 10A Data Channel Connection No of Echelon FTT 10A Data Channels 2 Echelon FTT 10A BANK A Channels 7 and 8 Echelon FTT 10A BANK B None Connector 37 way D Type...

Страница 6: ...ransitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V pres...

Страница 7: ...nto the optical fibre Data Present OUT Green Data channel present but not transmitting R G Data channel receiving Off Data channel not present or no connection OUT corresponds to the data signals bein...

Страница 8: ...A level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively It is important therefore to terminate the RS 485 bus or the RS 422 input bus using 120 if a pre bias is...

Страница 9: ...ently as required The 3 examples shown are RS 232 no termination RS 422 120 or RS 485 120 Alarm Channel Configuration The AMG5904A966B9 provides 8 bi directional contact closure inputs alarm outputs E...

Страница 10: ...6 IN ALARM 2 6 OUT 3 GND GND 4 ALARM 3 7 IN ALARM 3 7 OUT 5 ALARM 4 8 IN ALARM 4 8 OUT Audio Channel Configuration The AMG5904A966B9 provides fourteen bi directional audio channels Each audio channel...

Страница 11: ...A B 5 Audio CH3 IN A B 24 Audio CH3 OUT A B 6 Audio CH3 IN A B 25 Audio CH3 OUT A B 7 Audio CH4 IN A B 26 Audio CH4 OUT A B 8 Audio CH4 IN A B 27 Audio CH4 OUT A B 9 GND A B 28 GND A B 10 GND A B 29...

Страница 12: ...tems in accordance with EN 60825 2 2000 It is always advisable to follow good practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved c...

Отзывы: