AMG AMG5526 Скачать руководство пользователя страница 4

AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 4 of 8 

AMG5526 Instruction Sheet D17299-
00.doc 
 

 

 

Connections 

Optical Connections Singlemode 

No. of Optical Connections .................. 1 per channel 
Optical Fibre ........................................ Singlemode  
Connector ............................................ SC/PC 
 
Primary Optical Launch Power ............ -10dBm 
Transmit Wavelength ........................... 1550nm 
 
Primary Optical Sensitivity ................... -30dBm 
Receive Wavelength ............................ 1310nm 
 
Minimum Optical Dynamic Range ....... 20dB. 
 

 

Power Connection 

Connector Type ................................... Removable 2-pin, 3.81mm, Screw Terminal  
Connector Partno. ................................ Phoenix 1803578 
Supply Voltage ..................................... +12 to +15 Volts DC  
Maximum Power .................................. 2.5 Watts 
 

 

Data and Alarm Channel Connections 

No. of Data Channels .......................... 1 per channel. 
No. of Alarm Outputs ........................... 2 per channel. 
 
Connectors .......................................... Removable 8-pin, 2.5mm, Screw Terminal 
Connector Partno. ................................ Phoenix 1881383 
 
Data Interfaces .................................... RS-232, RS-422 or R-S485. Selected by slide switch inside 

enclosure. *See appropriate section on how to remove the case 
for access to the data switches 
 

 

RS-485 – Switch Position - Top  

 

RS-422 – Switch Position - Middle 

 

RS-232 – Switch Position - Bottom 

 
Alarm Output ........................................ Solid-state Relay, maximum 150mA at 125Vac/dc,  Ron < 6.5Ω 
 
 
 

 

Содержание AMG5526

Страница 1: ...l and two Uni directional Alarms for a Singlemode Fibre Link The AMG5526 is a DUAL standalone system which provides two independent channels each designed to receive 2 uni directional alarms and trans...

Страница 2: ...Optical Connection 3 Connections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data LEDs 5 Alarm LEDs 5...

Страница 3: ...ceive channels Each channel receives 1 data and 2 uni directional alarm signals from up to two AMG5515 single channel or one dual channel transmit unit It also transmits 1 data signal to each AMG5515...

Страница 4: ...Optical Dynamic Range 20dB Power Connection Connector Type Removable 2 pin 3 81mm Screw Terminal Connector Partno Phoenix 1803578 Supply Voltage 12 to 15 Volts DC Maximum Power 2 5 Watts Data and Alar...

Страница 5: ...ansitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V prese...

Страница 6: ...ce defined by the corresponding mode switch inside the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS...

Страница 7: ...iddle RS 232 switch bottom 1 IN A IN 2 IN B 3 GND GND GND 4 5 6 7 IN OUT A OUT A 8 IN OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Channe...

Страница 8: ...g screws on the rear panel and slide the PCB sufficiently out of the case to enable access to the switch To replace the PCB into the case slide the PCB gently into the case if necessary aligning the b...

Отзывы: