Setting the time zone
The time zone of the device can be set with the following command and depends on the
Coordinated Universal Time (abbreviation UTC).
The command is
TZ
immediately followed by the desired modifier, two digits with + and -
before.
For the German summer time is the order:
TZ + 02
For the German winter time it is:
TZ + 01
The correct time display requires the connection to the GPS satellite. Subsequently, the
time automatically adjusts itself correctly based on the time zone.
Power saving settings
You can choose between 2 different modes.
Send
PS1
as SMS text to the GPS emergency transmitter. This mode is preset.
In this mode, SMS and calls can be received. The GPS chip works only when a position
change takes place. If the emergency transmitter is not moved, it saves electricity.
If an emergency call is issued, the current position is transmitted immediately.
Send
MODE4
as SMS text to the GPS emergency transmitter to increase the battery life.
In this mode, SMS and calls can be received. The GPS chip is put in a "sleep mode",
which increases the battery life. As soon as the SOS button is pressed, the GPS position
search starts and the GPS is put back into the energy-saving mode after successful
locating.
If an emergency call is issued, the SMS command
LOC
must be sent to the emergency
transmitter to get the current position.
Fall sensor
The main module
of the NR-03 has an integrated case sensor, which can optionally be
activated via SMS command (and deactivated again).
This fall sensor makes it possible to automatically drop off an SMS, or an SMS and a call
to all programmed subscribers when the carrier falls. The SMS will send a Google Maps
link with the last available position.
Please note that a fall sensor is a very inaccurate type of triggering, it can not be
guaranteed that the fall sensor triggers in any emergency, usually a drop height of 1m
and a change in position of the sensor of 45 ° is specified as a trigger criterion.
Functionality:
As soon as the case has been registered, the device starts to beep at short intervals, in
the case of an unwanted trip you now have the option of canceling the alarm by pressing
the SOS button. Otherwise, depending on the setting, an SMS with the message "Fall
Down Alert!" And a Google Maps link of the last ascertainable position, or the SMS and a
call to all programmed subscribers will be sent.