CONTROLS & PROGRAM DESCRIPTION
Press key
F1
and enter into next parameters of back tack for cycle start in Screen 4.2.d8.
Fwd Drive Speed – 1
Time – 0.0s Index - 1
Screen 4.2.d8
There are 3 parameters on this screen.
a)
Fwd Drive Speed: This is the DC motor speed during the jig movement from point
A to B.
b)
Time: This is a time parameter in seconds. During this time DC motor will rotate to move
the jig from point A to B.
c)
Index: This parameter is an integer value to select different stitch densities. But in Screen
4.2.d8 this parameter will be active only in case of “Z Type” back tack (Screen 4.2.d26)
and if parameter Fwd Drive Speed is set ‘0’. It means jig movement from A to B in “Z
Type” back tack is not controlled by DC motor and is intended to be controlled with main
sewing motor. In case Fwd Drv Speed selected other than ‘0’ the parameter “Index” will
hide and display will show
‘****’
. When performing whole stitching operation with main
‘Z’ Type Back Tack
Pwd speed
Back Tack
A
B
C
B
C
Side 1
No Stitch
Stitch
sewing motor only, then stitch density may be controlled by three index values 0,1 and 3.
Press key
F1
to enter Screen 4.2.d13 for Side1 parameters.
Index 1
Index 2
Index 3
Stitch Density with Sewing Head Motor