Ametek TAYLOR HOBSON Surtronic S-100 Series Скачать руководство пользователя страница 49

49

English

Keyboard

1.  The main alphabet keyboard is split into two. The alphabet 

characters that have the bigger font are the characters that are 
active at the time. To switch between the top left and bottom 
right characters, tap the ‘Keyboard’ icon

2.  Tap ‘number’ or ‘symbol’ icons to enter either numbers or symbols 

in the batch name.

View batch 

1.  Tap ‘Store’ and then ‘View Batch’ to view all internally saved data.

Where there are more than 10 batch files stored, they will be 
displayed over more than one page.

2.  Tap the batch name to view the data in more detail.

Содержание TAYLOR HOBSON Surtronic S-100 Series

Страница 1: ...Surtronic S 100 Series User Guide English Deutsch...

Страница 2: ...er Guide This isTaylor Hobson s User Guide for the Surtronic S 100 Series All the specifications in this document are correct at time of production and are subject to change Please contactTaylor Hobso...

Страница 3: ...ng 24 Declaration of conformity 25 Environmental legislation 26 Surtronic S 100 series dimensions 27 Quick start guide 28 Using the instrument 30 Basic operation 32 Filter 37 Evaluation length 38 Para...

Страница 4: ...faces or bench mounted with fixturing for batch measurement and laboratory applications Any surface any height The inclusion of a 50 mm stylus lift with right angle attachment and more than 70 mm styl...

Страница 5: ...nectivity options to many standard devices USB type A TheType A USB port can be used to attach a portable printer ESC POS compatible see Accessories page or a standard USB storage device for recording...

Страница 6: ...asurement with cylinder axis Rubberised moulding Added protection and better grip in the hand invaluable in shop floor environments Orientation Rotate the display to any of of 4 orientations perfect f...

Страница 7: ...up to 2000 measurements from a single charge InstantOn By utilising InstantOn technology these instruments are ready to measure in less than 1 second from standby and fully charged can remain in stan...

Страница 8: ...ofile Silver has enhanced features for R W parameters a statistics module and full report printing andTalyProfile Gold has complete laboratory analysis functions Lite Silver Gold Surtronic S series ac...

Страница 9: ...ata import Tolerance limits pass fail Data file explorer ISO 13565 Automotive Interactive MR curve Step height measurement Form removal Filtering by FFT Thresholding Frequency spectrum Power spectrum...

Страница 10: ...e desk top publishing function which allows clear presentation of measurements results and profiles Graphs profiles and results can be arranged from within theTalyProfile software or copied into other...

Страница 11: ...port using the software s detailed analysis options and desktop publishing function In depth analysis Profiles can be levelled and zoomed to remove unwanted features or defects from the analysis Dista...

Страница 12: ...Psk Pku PSm Pdq Pmr Pdc PPc Wp Wv Wz Wc Wt Wa Wq Wsk Wku WSm Wdq Wmr Wdc WPc ISO 13565 Lite Silver Gold Rk Rpk Rvk Mr1 Mr2 Ppq Pvq Pmq Rpq Rvq Rmq ISO 12085 Lite Silver Gold R AR Rx Pt Kr Nr SR SAR W...

Страница 13: ...PTp PHTp Pfd Ppm RLq Rda RLa RLo RzJIS R3z Rmax Rtm Ry RH RHSC RD RS Rvo Rrms RTp RHTp Rfd Rpm WLq Wda WLa WLo WzJIS W3z Wmax Wtm Wy WH WHSC WD WS Wvo Wrms WTp WHTp Wfd Wpm Applicative parameters Lit...

Страница 14: ...ted column providing adjustment height of 260 mm USB thermal printer Code PR 60 Compact highspeed 60 mm 24 in second Includes USB lead and International Power Supply Outputs settings results and high...

Страница 15: ...of 430 mm and a range of 115 mm at a horizontal reach of 305 420 mm Portable base Code SA 40 This provides a support when used on machine tool applications Datum support stand Code SA 90 Provides an...

Страница 16: ...r use with the Datum Support Stand Precision vice Code SA 31 High quality precision vice ideal for holding small components Jaw width 63 mm jaw depth 32 mm jaw opening 85 mm Hard transport case Code S...

Страница 17: ...r controlled lifting and lowering of the pickup to aid measurement setup S Series mains adaptor Code SC 10 International USB charger 5V 1A 110 240VAC 50 60Hz Recharges S116 S128 in 4 hours Calibration...

Страница 18: ...n deep holes 100 mm extension reach 160mm Code SA 25 200 mm extension reach 260mm Code SA 28 Dot Matrix printer Code PR 40 Robust high speed high performance easy to use printer with USB connection Do...

Страница 19: ...ign and manufacture pick ups for specific requirements Standard pick up For general surface roughness measurement Code PK 02 5 m tip radius Code PK 03 10 m tip radius Small bore pick up Code PK 01 For...

Страница 20: ...ecess pick up For measuring into deep recesses Code PK 06 recess 5 7 mm 0 23 in with 5 m tip radius Code PK 08 recess 25 mm 0 23 in with 5 m tip radius Other depths and tip radii available Chisel edge...

Страница 21: ...21 English Side skid pick up Code PK 31 For use on curved surfaces such as gear teeth Shoe pick up Code PK 99 For measuring rougher surfaces particularly with the 2 5mm 0 1in cut off 60 7 66 1...

Страница 22: ...lyProfile Data storage Internal 100 measurement results 1 raw profile USB 4GB supplied 39 000 raw profiles up to 100 000 results per batch 70 batches PC connection Unlimited data storage SPC stats Int...

Страница 23: ...C 32 122 F Humidity 0 80 non condensing Analysis capacity Instrument S 116 S 128 Parameters Standards ISO 4287 ISO 13565 1 ISO 13565 2 ASME 46 1 JIS 0601 N31007 ISO basic Ra Rv Rp Rz Rt Rq Rsk Rmr Rdq...

Страница 24: ...to calibrate to ISO 4287 roughness standards Analysis Filter cut off 0 25 mm 0 8 mm 2 5 mm Filter type 2CR Gaussian Evaluation length 0 25 mm 17 5 mm 0 01 in 0 70 in 0 25 mm 25 0 mm 0 01 in 1 00 in Ma...

Страница 25: ...25 English Declaration of conformity...

Страница 26: ...rces End users in the UK and Republic of Ireland As the manufacturer Taylor Hobson is responsible for the safe disposal of equipment at end of life Taylor Hobson are registered with the UK Environment...

Страница 27: ...English Surtronic S 100 series dimensions 303 mm with standard 112 1502 pick up attached 237 mm without pick up 81 mm 57 mm 36 mm 25 5 mm max travel 4 fixturing holes 25 mm 30 mm 2 5 mm 152 mm 87 mm 4...

Страница 28: ...0 3 6809 2406 taylor hobson japan ametek com Taylor Hobson Korea Tel 82 31 888 5255 taylor hobson korea ametek com Taylor Hobson China Beijing Office Tel 86 10 8526 2111 taylor hobson beijing ametek c...

Страница 29: ...1531 part no 112 1599 60 2 6 part no 112 4701 60 C 80 0 00 6 66 1 6 60 7 7 1 7 1 3 12 7 5 talyprofile com Taylor Hobson UK Tel 44 116 276 3771 taylor hobson uk ametek com Taylor Hobson France Tel 33 1...

Страница 30: ...tate 35 Screen shot 35 Graph 36 Battery 36 Memory 36 Filter 37 Filter c type 37 c Cut off 37 Evaluation length 38 Parameters 38 Parameters 38 Parameter settings 40 Range 42 Units 43 Calibration 43 Cal...

Страница 31: ...batch 48 Keyboard 49 View batch 49 Delete batch 50 Print batch 50 Print settings 51 Model 51 V Scale 51 Advanced 52 Language 52 Auto print 52 Power saving 53 Stylus return 55 Test mode 55 Set zero 56...

Страница 32: ...tion Overview Power Measure Button On Off Hold for 3 seconds Measure Press for 3 Seconds Icon bar Profile Battery level Instrument type Results Page indicators Rotate icon Gauge indicator Shortcuts sh...

Страница 33: ...own arrow to scroll down through the menu Device Icons Tap the arrow icon to move down to the next item in a list Tap the tick icon to confirm your selection or data input Tap the return icon to retur...

Страница 34: ...e 37 for more information Filter c type Tap the Filter icon to edit the type See page 37 for more information Evaluation length Tap the measurement icon to edit the length See page 38 for more informa...

Страница 35: ...mode in 4 different orientations Screen shot 1 Tap the Taylor Hobson icon to take a screen shot of what is shown on the device screen at that time 2 For this function to work an external USB or stora...

Страница 36: ...Surtronic S Series current battery life This icon indicates the Surtronic S Series battery is charging Memory Internal memory This icon indicates the activated mode where any measured data is saved t...

Страница 37: ...37 English Filter Filter c type Tap menu and Filter Then select cType to select the filter type c Cut off Tap menu and Filter Then select c Cut off to select the c Cut off size...

Страница 38: ...length Select required N number of cut offs and the new length c x N will be calculated automatically Parameters Tap Parameters in menu to select parameters based on different standards as given belo...

Страница 39: ...39 English ISO 13565 Tap ISO 13565 to select parameters ASME B46 1 JIS B 0601 Tap ASME B46 1 or JIS B 0601 to select parameters Others Tap Others to select parameters...

Страница 40: ...s in Menu then ISO 4287 R and then the first settings icon to open the Rmr Settings Mr Tap Mr and then the box where the number is displayed to adjust the setting Tap on the Up Down arrows to edit the...

Страница 41: ...setting 2 Tap icon to toggle between positive and negative Tap Up Down arrows to change the number in the offset box Rmr settings Meanline Tap Meanline to adjust the setting Tap icon to select between...

Страница 42: ...42 English Rpc Tap ISO 4287 R and then the Settings icon next to Rpc to adjust the Rpc Bandwidth Tap Up Down arrows to cadjust the value of the bandwidth Range Tap menu and Range to select the range...

Страница 43: ...3 English Units In Menu tap Units to select between Metric and English Calibration Calibration settings Tap Calibration on the main menu and then the settings icon to see a list of calibration options...

Страница 44: ...he calibration Ra value You can also access the calibration value screen by tapping the calibration value box on the main calibration screen Calibration filter Type Tap Filter and then c Type to selec...

Страница 45: ...lt value is 0 80mm c settings Tap c Settings to set the required calibration evaluation length and adjust the c Cut off if necessary Set the calibration length by tapping the box next to N for the num...

Страница 46: ...ton to initiate the calibration measurement When the measurement is complete the measured Ra value will be displayed as well as the calculated error To complete the calibration process tap the calibra...

Страница 47: ...measurement results to be stored internally in the unit USB Allows subsequent measurement results to be stored on an external data stick Results are saved as txt file format USB Raw Allows subsequent...

Страница 48: ...red measurements 2 Enter batch name using alpha numeric keyboard and tap save The name must be 5 characters or less All subsequent measurements will be saved using this batch name with auto numeric in...

Страница 49: ...tween the top left and bottom right characters tap the Keyboard icon 2 Tap number or symbol icons to enter either numbers or symbols in the batch name View batch 1 Tap Store and then View Batch to vie...

Страница 50: ...deletion of the batch Tap All to select all batch files Tap the trash icon to delete all batches Print batch A compatible printer must be connected and switched on to activate this feature 1 Tap Stor...

Страница 51: ...rinter is detected connected to the device Tap printer icon on the home screen to print the measurement Model In Print Settings tap Model to select the printer model Tap the back arrow icon to accept...

Страница 52: ...anced and then Language to select which language you require Auto print Allows the unit to send measurement results automatically to the printer with each measurement if switched on Tap Advanced and t...

Страница 53: ...a maximum of 6 hours in pre set increments Another option is to select Never if the sleep timer feature is not desired Battery 1 Tap advanced then power saving and then sleep timer 2 Select Battery an...

Страница 54: ...Saving and then select Brightness 2 Set the brightness of the screen to the percentage you require by using the Up Down arrows Battery level Tap Advanced then Power Saving and then select Battery Leve...

Страница 55: ...ws the user to control when the stylus returns after each measurement Test mode Test mode initiates a series of internal tests and checks the unit for diagnostic purposes This should be used byTaylor...

Страница 56: ...the stylus tip is in contact Take a measurement after set up and the indicator should reset with the arrow set to the middle of the range Licence This allows the unit configuration to be changed for...

Страница 57: ...e Device Lock menu enter a 4 digit PIN of your choice and press the tick icon to accept and lock The lock icon should now appear at the top of the screen To unlock press the locked menu icon and re en...

Страница 58: ...k com Taylor Hobson France Rond Point de l Epine Champs Batiment D 78990 Elancourt France Tel 33 130 68 89 30 Fax 33 130 68 89 39 taylor hobson france ametek com Taylor Hobson Germany Rudolf Diesel St...

Отзывы: