Status Byte
The Status byte register contains the STB and RQS (MSS) messages as
defined in 488.1. You can read the status byte register using a 488.1
serial poll or the 488.2 *STB? common command.
The *STB? query causes the device to send the contents of the Status
Byte Register and the Master Summary Status (MSS) summary
message. The *STB? query does not alter the status byte, MSS, or RQS.
Table 5-10
Status Byte Summary Register
Bit
Bit
Weight
Bit Name
Description
0
1
Reserved
Reserved
1
2
Reserved
Reserved
2
4
Error/Event Queue (ERR)
Set if any errors are present in the Error/Event queue.
3
8
Questionable Status
Register (QSR)
Set if any bits are set in the Questionable Status Event
register.
4
16
Message Available
(MAV)
Indicates whether the output queue is empty. MAV is
TRUE if the device is ready to accept a request from the
controller.
5
32
Standard Event Status Bit
Summary (ESB)
A summary of the Standard Event Status Register.
6
64
Request Service (RQS) /
Master Status Summary
(MSS)
Not Implemented / MSS indicates that the device has at
least one reason for requesting service.
7
128
Operation Status Register
(OSR)
Present if a bit is set in the Operation status register.
Error/Event Queue (ERR)
This bit is TRUE if any errors are present in the Error/Event Queue.
Questionable Status Register Summary (QSR)
This bit is TRUE when a bit in the Questionable Event Status Register is
set and its corresponding bit in the Questionable Status Enable Register
is TRUE.
Содержание Sorensen XG 100-15
Страница 2: ......
Страница 21: ...1 Introduction Chapter 1 Introduction describes the features of the XG Family Programmable DC Power Supply ...
Страница 93: ...Local Operation M370430 01 Rev F 3 47 3 Figure 3 5 Series Operation ...
Страница 99: ...Local Operation M370430 01 Rev F 3 53 3 ...
Страница 100: ...Local Operation 3 54 M370430 01 Rev F ...
Страница 220: ...Communications Options 6 14 M370430 01 Rev F ...
Страница 224: ...Communications Options 6 18 M370430 01 Rev F 9 In the Setup Type window choose Typical and click Next ...
Страница 225: ...Communications Options M370430 01 Rev F 6 19 6 10 Check that your Settings are correct and then click Install ...
Страница 232: ...Communications Options 6 26 M370430 01 Rev F 9 In the Setup Type window choose Typical and click Next ...
Страница 244: ...Communications Options 6 38 M370430 01 Rev F ...
Страница 252: ...Communications Options 6 46 M370430 01 Rev F ...
Страница 292: ......
Страница 329: ...M370430 01 Rev F A 37 A APPENDIX A SCPI Command Reference ...
Страница 330: ......
Страница 348: ...APPENDIX C Specifications C 12 M370430 01 Rev F Figure C 2 XG 850 Watt Mechanical Dimensions 60 V to 600 V Models ...
Страница 349: ...APPENDIX C Specifications M370430 01 Rev F C 13 Figure C 3 XG in Full Rack Mechanical Dimensions 6 V to 40 V Models ...
Страница 351: ...APPENDIX C Specifications M370430 01 Rev F C 15 Figure C 5 XG in Full Rack Mechanical Dimensions 60 V to 600 V Models ...
Страница 354: ...APPENDIX C Specifications C 18 M370430 01 Rev F Figure C 9 XG850 Low Voltage Model Dimensions Top Side and Rear ...
Страница 361: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 5 Figure D 3 RM XG1 Rack Rails ...
Страница 367: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 11 Figure D 10 Installing Chassis ...
Страница 368: ...APPENDIX D Rack Mount Options and Installation Instructions D 12 M370430 01 Rev F ...
Страница 369: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 13 ...
Страница 370: ......
Страница 395: ...Rack Mount Options and Installation Instructions M370430 01 Rev F E 25 ...
Страница 396: ......
Страница 399: ......