Rear Panel Connectors and Switch
TM-F2OP-C1XN-01
1-7
Resetting the Switches
Before making any changes to the switch settings, disable the power
supply output by pushing the front panel STANDBY switch to its IN
position. This temporarily shuts down the power supply. The front panel
S/D LED turns on. Then, use any small, flat-bladed screwdriver to change
the switch settings.
Any of the eight switches on SW1 is OFF when it has been flipped up to
break contact, ON when flipped down to close contact.
Rear Panel J2 Connector
The J2 Programming and Monitoring connector is a 15-terminal wire
clamp connector located on the power supply’s rear panel. See Figure 1-4.
The J2 connector provides access to the following functions:
•
Remote programming of output voltage AND/OR current limit
•
Remote monitoring of calibrated readback signals for output voltage
and output current
•
Remote control of the shutdown function using a 2.5 V to 15 V signal
See Table 1-3 for the
list of the J2 connector terminal numbers, their
references, and corresponding functions.
Figure 1-4
Programming and Monitoring J2 Connector
1
Remote Output Voltage Programming Select
2
Remote Output Current Limit Programming Select
3
Control Ground
4
No connection
5
Voltage Program Signal Return
6
Output Voltage Programming Input
7
Current Program Signal Return
8
Output Current Limit Programming Input
9
Voltage Monitor Signal Return
10
Output Voltage Monitor
11
Current Monitor Signal Return
12
Output Current Monitor
13
No connection
14
Shutdown (S/D) Signal Return (–)
15
S/D Input (+)
Содержание Sorensen XFR 100-28
Страница 3: ...This page intentionally left blank ii...
Страница 5: ...This page intentionally left blank iv...
Страница 7: ...This page intentionally left blank vi...
Страница 13: ...xii...
Страница 15: ...xiv...
Страница 25: ...1 10...
Страница 67: ...3 18...
Страница 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Страница 75: ...4 8...
Страница 87: ...5 12...