Congratulations on the purchase of your new Reichert

®

 PSL Portable Slit Lamp. 

This User’s Guide is designed as a training and reference manual for operation, mainte-

nance, and troubleshooting.  We recommend that you read it carefully prior to use and 

follow the instructions in the guide to ensure optimum performance of your new instrument.   

Properly trained eye care professionals such as ophthalmologists, optometrists, opticians 

and eye care technicians should operate this instrument.  This unit should only be used by 

personnel knowledgeable of its operation and use.  

Please retain this guide for future reference and to share with other users.  For additional 

copies of this manual or questions related to the PSL, contact your local authorized Reich

-

ert Technologies

®

 dealer or contact our Customer Service department directly at:   

Tel:   716-686-4500

Fax:    716-686-4555

E-mail: [email protected]

Indications for Use

A slit lamp biomicroscope is intended for use in eye examination of the anterior eye seg-

ment, from the cornea epithelium to the posterior capsule.  It is used to aid in the diagnosis 

of diseases or trauma which affect the structural properties of the anterior eye segment.

Contraindications

None.

Introduction

Содержание Reichert PSL

Страница 1: ...PSL Portable Slit Lamp User s Guide...

Страница 2: ...in this manual without notice and without incorporating those changes in any products already sold ISO 13485 Certified Reichert products are designed and manufactured under quality processes meeting...

Страница 3: ...ification 11 Battery Installation 13 Eyepiece Check 13 Operating Instructions 14 Focusing and Adjusting Interpupilary Distance IPD 14 Illumination Control 15 Slit Width 16 Selecting a Filter 16 Forehe...

Страница 4: ...ANY REPAIR OR SERVICE TO THIS INSTRUMENT MUST BE PERFORMED BY EXPERIENCED PERSONNEL OR DEALERS WHO ARE TRAINED BY REICHERT OR SERIOUS INJURY TO THE OPERATOR OR PATIENT MAY OCCUR WARNING MODIFICATIONS...

Страница 5: ...HOCK THIS EQUIPMENT MUST ONLY BE CONNECTED TO A SUPPLY MAINS WITH PROTECTIVE EARTH OR DAMAGE TO THIS INSTRUMENT AND OR INJURY TO THE OPERATOR OR PATIENT MAY OCCUR WARNING THE INSTRUMENT MUST BE PLUGGE...

Страница 6: ...HE RISK MAY ALSO BE INCREASED IF THE PERSON BEING EXAMINED HAS HAD ANY EXPOSURE WITH THE SAME INSTRUMENT OR ANY OTHER OPHTHALMIC INSTRUMENT USING A VISIBLE LIGHT SOURCE DURING THE PREVIOUS 24 HOURS TH...

Страница 7: ...FULLY CHARGED AT THE FACTORY CHARGE THE BAT TERY BEFORE USE CAUTION WHEN RECHARGING THE BATTERY THEAMBIENT TEMPERATURE SHOULD BE BETWEEN 5 35 C 41 95 F OR THE BATTERY MAY NOT FULLY CHARGE OR MAY NOT...

Страница 8: ...ical and Electronic Equipment REF Catalog Number SN Serial Number Consult Instructions for Use symbol indicating important operating and maintenance instructions that are included in this User s Guide...

Страница 9: ...be used by personnel knowledgeable of its operation and use Please retain this guide for future reference and to share with other users For additional copies of this manual or questions related to the...

Страница 10: ...he box 2 Remove the following parts from the box Refer to Figure IS 01 PSL Portable Slit Lamp PN 15090 Accessories Carrying Case PN 15090 009 2 Rechargeable Batteries PN 15090 401 or 15090 403 Battery...

Страница 11: ...with the PSL 3 Rechargeable Batteries PSL comes with 2 rechargeable batteries so that one can always be charging while the other is in use 4 Diopter Adjustment Bar This is used to ensure your PSL is f...

Страница 12: ...umination Column Illumination ON OFF Switch Hand Grip Focusing Bar Forehead Support Screw Hole Filter Dial Slit Width Control Ring Illumination Intensity Dial Left Right Eyepieces Battery Slot Battery...

Страница 13: ...mination ON OFF switch located on the hand grip When you squeeze the illumination switch the green battery indicator LED will light up Note Remove the battery from the PSL when not using the PSL for a...

Страница 14: ...t Refer to Figure OI 02 3 Adjust the IPD by moving the left and right Oculars until the image on the Focusing Bar is one image seen with both eyes Refer to Figure OI 03 4 Adjust the left and right Eye...

Страница 15: ...fer to Figure OI 05 The Illumination Intensity Dial is located on the main body of the PSL directly under the Oculars Rotating the Illumination Intensity Dial to the right will increase the PSL illumi...

Страница 16: ...he filter in place Refer to Figure OI 08 The four filter options are No Filter Green Cobalt Blue Color Temperature Conversion Forehead Support To use the Forehead Support attach the Forehead Support t...

Страница 17: ...e PSL comes with 10X and 16X Eyepieces The 10X Eyepieces are pre installed Turn each Eyepiece counterclockwise to remove it from the PSL and carefully put them away in the Carrying Case Screw the repl...

Страница 18: ...ousing using a lint free cotton cloth lightly dampened with a mild cleaning solution that is safe for plastic Be sure to wipe off any residual solution using a lint free cotton cloth moistened with cl...

Страница 19: ...e Slit Width Control Ring so that the slit width is open Image blurry when looking through eyepieces Eyepieces dirty Clean the eyepieces Refer to the Cleaning Maintenance section Microscope Objective...

Страница 20: ...in 80 mm Slit Width 0 0 43 in 0 11mm Slit Length 0 43 in 11mm Filters Cobalt Blue Green Color Temperature Conversion Slit Rotation 30 Light Source High Luminance White LED Battery PN 15090 401 Li ion...

Страница 21: ...F Relative Air Humidity 10 to 95 Atmospheric Pressure 70 kPa 20 7 in Hg to 106 kPa 31 3 in Hg Disposal This product and the lithium ion battery inside it do not generate any environmentally hazardous...

Страница 22: ...product PATENT WARRANTY If notified promptly in writing of any action brought against the purchaser based on a claim that the instrument infringes a U S Patent Reichert will defend such action at its...

Страница 23: ...15090 101 REV H 23 Notes...

Страница 24: ...86 4545 Email reichert information ametek com www reichert com Authorized European Representative AMETEK GmbH Business Unit Reichert Carl von Linde Strasse 42 85716 Unterschleissheim Munich Germany Em...