44
If this value is less than 65535, then the transmitter may send data representing more
than 100% for metering values that can exceed 100% of the nominal unit rating.
3.12.8
Main Menu >> Service-Parameter Configuration Menu >> Miscellaneous
Ramp Up Time and Ramp Down Time limit the rate at which the setpoint will change
based on the rate of change required to adjust the full range of the setpoint within the
time entered.
NetFaultMode establishes the mode of operation on loss of network communication
(no established connections).
0 = Fault and Stop, bit automatically set in ‘Fault Mask’. Clears ‘NetCtrl’, ‘NetRef’,
‘Run1’, ‘Remote Relay Req’, ‘Net PFZF Select’, and ‘Net_Setpoint’.
1 = Ignore (Warning optional depending on bit setting in ‘Warning Mask’). This will
allow the controller to continue in its current operation mode at time of network
event. If running from network control, ‘NetCtrl’, ‘NetRef’, ‘Run1’, ‘Remote Relay
Req’, ‘Net PFZF Select’, and ‘Net_Setpoint’ will remain unchanged.
2 = Clears ‘NetCtrl’, ‘NetRef’, ‘Run1’, ‘Remote Relay Req’, ‘Net PFZF Select’, and
‘Net_Setpoint’. Does not Fault and Stop. Resulting operation will depend on
internal/local controls. (Warning optional).
NetIdleMode establishes the mode of operation on reception of network Idle
communication.
0 = Fault and Stop, bit automatically set in ‘Fault Mask’. Clears ‘NetCtrl’, ‘NetRef’,
‘Run1’, ‘Remote Relay Req’, ‘Net PFZF Select’, and ‘Net_Setpoint’.
1 = Ignore (Warning optional depending on bit setting in ‘Warning Mask’). This will
allow the controller to continue in its current operation mode at time of network
Содержание MP3 SCR DeviceNet Head
Страница 2: ......
Страница 5: ...iii COPYRIGHT 2011 HDR POWER SYSTEMS INC...
Страница 9: ...2 Blank Page...
Страница 28: ...21 3 6 1 Main Menu Metering Menu Metering General...
Страница 30: ...23 3 6 3 Main Menu Metering Menu Time Counter KW Hour Meter 3 7 Main Menu Event Log Menu...
Страница 44: ...37 3 12 5 Main Menu Service Parameter Configuration Menu Alarm Setup...
Страница 45: ...38...
Страница 55: ...48 3 12 10 Main Menu Service Parameter Configuration Menu Serial Ports...
Страница 59: ...52...
Страница 60: ...53...
Страница 64: ...57...
Страница 65: ...58...
Страница 66: ...59...
Страница 68: ...61 3 13 6 Main Menu Service Analog Calibration Menu General Analog Calibration Menu Analog Feedback Calibration...