18
I
II
III
IV
V
VI
VII
VIII
IX
LEVEL
MATE II
TRANSMITTER
INPUT TYPE
4-20 mA
INCHES OF
WATER
COUNT
BY
FEET OF
WATER
COUNT
BY
METERS
OF WATER
COUNT
BY
LMT100 575SB0006RLS(50)
rdLO
00.0
1
0.00
1
.000
5
rdHI
166.4
1
13.86
1
4.226
5
LMT200 575SB0015RLS(75)
rdLO
00.0
2
0.00
2
0.00
1
rdHI
415.9
2
34.66
2
10.56
1
LMT300 575SB0030RLS(100)
rdLO
00.0
5
0.00
5
0.00
2
rdHI
831.9
5
69.32
5
21.13
2
LMT400 575SB0060RLS(200)
rdLO
00.0
1
0.00
5
rdHI
138.6
1
42.26
5
LMT500 575SB0100RLS(300)
rdLO
00.0
2
0.00
5
rdHI
231.1
2
70.43
5
LMT600 575SB0150RLS(425)
rdLO
00.0
2
00.0
1
rdHI
346.6
2
105.6
1
LMT700 575SB0200RLS(550)
rdLO
00.0
5
00.0
1
rdHI
462.2
5
140.9
1
LMT800 575SB0300RLS(750)
rdLO
00.0
5
00.0
2
rdHI
693.2
5
211.3
2
I Level Mate II model number.
II Transmitter used. Cable length is in parentheses ( ).
III The input type to be selected is 4-20 mA.
IV Decimal point location and display reading entered for inches of water level measurements.
VI Decimal point location and display reading entered for feet of water level measurements.
VIII Decimal point location and display reading entered for meters of water level measurements.
V, VII & IX The display resolution (count by) that is recommended.
TABLE VI - LEVEL MATE II INPUT TYPE & DISPLAY SCALING