27

Installation and Maintenance Manual

Chapter 10: Wiring Diagrams

Fig 10-3  Wiring Diagram

Drawing E0234500

Содержание Gemco 1995L

Страница 1: ...Spec Tech Industrial 203 Vest Ave Valley Park MO 63088 Phone 888 SPECTECH Email sales spectechind com www spectechind com...

Страница 2: ...K has checked the accuracy of this manual at the time it was printed Any comments you may have for the improvement of this manual are welcomed AMETEK reserves the right to revise and redistribute the...

Страница 3: ...ctor 5 3 4 Number of Outputs 6 3 5 Selecting Number of Outputs 6 3 6 Multiprogram AvailableOnlyon P OptionUnits 6 3 7 Setpoint Formula 7 3 8Multi Program OnlyAvailableon P OptionUnits 7 3 9 Setpoints...

Страница 4: ...7 3 Grounding 18 7 4 Incoming Power 19 7 5 Low Level Inputs 19 Chapter 8 Specifications 20 8 1 1995 Micro Set PLS Programmer 20 8 2 Mechanical Relay Single Pole Double Throw 20 8 3 AC Solid State Sin...

Страница 5: ...rogrammableLimitSwitch PLS with a convenient keypad for programming each independent output circuit to open or close at thedesiredsettings Thissystemallowsprecisepositioncontroloflinearmotion A1995Lco...

Страница 6: ...can be panel mounted The controller consists of a keypad a CPU Board and a Power Supply I O Board The following features are found on the 1995L Micro Set n Display A 3 three digit LED readout and a 10...

Страница 7: ...plashing Panel cutouts mounting holes and sizes for each component are shown on Pages 6 and 7 of the 1995L catalogsection The controller should be mounted in the appropriate panel cutout and securely...

Страница 8: ...g LDT Wiring for this system is shown in Fig 10 1 Fig 10 2 and Fig 10 3 Chapter 10 Wiring Diagrams This wiring diagram is applicable for all standard 1995 PLSs 2 3 Wiring Instructions Attach the pre w...

Страница 9: ...cannotbechanged 3 2 Initialization The following key commands should be entered on the keypad to clear all programmed data upon installation and PRIOR to programming This sequence clearsallprogrammedd...

Страница 10: ...ofsix theunitwillstorethenextmultipleofsix 3 6 Multiprogram Available Only on P Option Units The Multiprogram feature allows the storage of multiple sets of output sequences that are preprogrammed bas...

Страница 11: ...of programs may need to be reduced Asetpoint is one CIR ON or CIR OFF entry Setpoint Programs 1467 2 Number of Programs x A S T U P T U O 6 S T U P T U O 2 1 S T U P T U O 8 1 S T U P T U O 4 2 S T U...

Страница 12: ...ecifiedearlierusing CIR 177 See Section 3 5 Selecting Number of Outputs C Depress The will set the selected relay turn on point D Depress This will set the selected relay turn off point E Multiple ON...

Страница 13: ...nts Thisisaccomplishedasfollows A Unitmustbeinthe Program mode B To clear all of the setpoints in the active program depress The active program is the program currently selected using Code 771 See Sec...

Страница 14: ...change to the position entered The display and outputs are now synchronizedwiththeactualmachineposition OFFSET ActualMachinePosition ENT 3 14 Reset to Preset Remote Reset to Preset Value This option a...

Страница 15: ...ay when the transducer speed exceeds the customer spreprogrammedvalue Themotiondetectorissetbyenteringthefollowing A Unitmustbeinthe Program mode B The motion detect must first be enabled before you c...

Страница 16: ...up if a one 1 is entered the unit will power up displayingScaleFactorincrements sec 3 17 Decimal Point Programming Acontinuous nonfloating decimal point may be programmed on the display If a scale fa...

Страница 17: ...Outputs CIR 380 or 381 ENT NOTE IfyoutrytodisabletheoutputsintheRunmode theunitwilldisplay EEE 3 18 Enable Disable Outputs During setup the outputs may be enabled or disabled When outputs are selecte...

Страница 18: ...be installed for the expansion module to operate Two pairs of pins located in the lower right corner of the expansion module should be jumpered on only the last module in the wiring group See Fig 10 4...

Страница 19: ...sinking device 5V DC at 10mA A normally closed momentary open contact button can be wired per Fig 10 1 Fig 10 2 OR Fig 10 3 Chapter 10 Wiring Diagrams to activate the Fault Check circuit and it will...

Страница 20: ...heoutputswillbeoffuntiltheproblemis corrected and the fault reset button is pressed and released to reactivate the fault output and return the display and outputs to their normal operation 2 If the fa...

Страница 21: ...Fig 10 2 OR Fig 10 3 Chapter 10 Wiring Dia grams forwiringoptions NOTE The 1995 PLS cannot be programmed until the security input has been actuated continuity between 5V DC and Security input and bet...

Страница 22: ...relays LDTand all interconnecting cables Once isolated the defective module should be replaced and returned to the factory for repair The1995PLS isdesignedforuseinanindustrialenvironmentandincorporate...

Страница 23: ...nd variable speed drives are all devices that generate excessive electricalnoisethroughoutthepowergridinatypicalindustrialenvironment Isolationtransformersor constant voltage type power supplies shoul...

Страница 24: ...og LDTo to 10Volt output 4 20mA available as special Logic Fault check and security 5V DC at 10mA May be operated by isolated contact current sourcing or current sinking device OUTPUTS Plug inrelaysli...

Страница 25: ...imumLoad 2 Amp DC LoadVoltage Range 5 to 60V DC Leakage Current 2mAMaximum On StateVoltage Drop 1 5VMaximum SurgeCurrent 5A 1 Sec Maximum Min OperationalCurrent 50 mA OperateTime 0 5msMaximum ResetTim...

Страница 26: ...t u O y a m y a l e r n o n r u t t n s e o d y a l e r e h t t u b s e t a r e p o 7 r e t p a h C w e i v e R y a l e r e c a l p e R d e l i a f e v a h g n i t o o h s e l b u o r T a t a d s s e...

Страница 27: ...a c t u p n i s i h t o t g n i r i w e h t n o e s i o n s t u p n I l e v e L w o L 5 7 n o i t c e S w e i v e r P s t e s e r a g n i m m a r g o r p n e h w s t n i o p l a m i c e d g n i h s a...

Страница 28: ...m a r g a i D g n i r i W 0 1 r e t p a h C 3 0 1 g i F R O 2 0 1 n a w o h s l l i w y a l p s i d e h t d e t c e t e d s i t l u a f a d n a d e l b a s i d e b l l i w s t u p t u o l l A E G A S...

Страница 29: ...25 Installation and Maintenance Manual Chapter 10 Wiring Diagrams Chapter 10 Wiring Diagrams Fig10 1 WiringDiagram Drawing E0221200...

Страница 30: ...Chapter 10 Wiring Diagrams Installation and Maintenance Manual 26 Fig10 2 WiringDiagram Drawing E0198202...

Страница 31: ...27 Installation and Maintenance Manual Chapter 10 Wiring Diagrams Fig10 3 WiringDiagram Drawing E0234500...

Страница 32: ...Chapter 10 Wiring Diagrams Installation and Maintenance Manual 28 Fig10 4 WiringDiagram Drawing E0204400...

Страница 33: ...1284 01 03 Z108 5C 1080 N Crooks Road l Clawson MI 48017 800 635 0289 l 248 435 0700 l Fax 248 435 8120 www ametekapt com l www ametek com...

Отзывы: