VII. 

SPECIFICATIONS

 

 

Parameter

 

Specification

 

Load Rating 

XG-PCS-15D 

15 Amps at 120 Volts 

XG-PCS-20D 

20 Amps at 120 Volts 

XG-PCS-20815D 

15 Amps at 208-240 Volts 

XG-PCS-20820D 

20 Amps at 208-240 Volts 

XG-PCS-23013 

13 Amps at 230V 

XG-PCS-L630 

30 Amps at 208-240 Volts 

XG-PCS-630 

30 Amps at 208-240 Volts 

Voltage Protection 
Rating (VPR) 

XG-PCS-15D 
XG-PCS-20D 

330V All Modes 

XG-PCS-20815D 
XG-PCS-20820D 

800V Line-Line 
500V Line-Ground 

XG-PCS-23013 

N/A 

XG-PCS-L630 
XG-PCS-630 

800V Line-Line 
500V Line-Ground 

Attenuation 

Normal 
Mode 

XG-PCS-15D 
XG-PCS-20D 
XG-PCS-20815D 
XG-PCS-20820D 
XG-PCS-23013 
XG-PCS-L630 
XG-PCS-630 

> 30 dB   80kHz 

– 50MHz 

Common 

Mode 

XG-PCS-15D 
XG-PCS-20D 

> 30 dB   70kHz 

– 50MHz 

XG-PCS-20815D 
XG-PCS-20820D 
XG-PCS-23013 
XG-PCS-L630 
XG-PCS-630 

> 30 dB   200 kHz 

– 50MHz 

Power Requirement 

(no load) 

XG-PCS-15D 
XG-PCS-20D 
XG-PCS-20815D 
XG-PCS-20820D 
XG-PCS-23013 

4 Watts 

XG-PCS-L630 
XG-PCS-630 

6 Watts 

Under-Voltage 
Shutdown 

120V Models 

Adjustable from 80V to 95 V, or Disabled. Restores at 105V. 

208-240V Models 

Adjustable from 140V to 170 V, or Disabled. 

Restores at 

190V. 

Over-Voltage 
Shutdown 

120V Models 

Adjustable from 135V to 160V. Restores at 130V. 

208-240V Models 

Adjustable from 260V to 300V. Restores at 250V. 

Internal Memory Capacity 

60 Events with timestamp; 999 counts of each event type 

Timestamp Accuracy 

± 2.5% 

Voltmeter Accuracy 
(Peak Reading Type) 

120V Models 

± 5% Typical product accuracy between 40V and 180V 

208-240V Models 

± 5% Typical product accuracy between 100V and 300V 

Response Time 

Over-Voltage 

100 msec 

Under-Voltage 

150 msec 

Under-Voltage 
Record Definition 

120V Models 

AC Voltage has dropped below 100V 

208-240V Models 

AC Voltage has dropped below 180V 

Over-Voltage Record 
Definition 

120V Models 

AC Voltage has risen above 135V 

208-240V Models 

AC Voltage has risen above 260V 

Power Outage Event Definition 

AC Voltage has dropped below 20V 

Содержание ESP Next Gen PCS

Страница 1: ...2022 AMETEK Electronic Systems Protection Technical Support 800 645 9721 espsurgex com U M N e x t G e n R e v G User Manual 120 and 208 240 Volt Models...

Страница 2: ...2022 AMETEK Electronic Systems Protection Technical Support 800 645 9721 espsurgex com U M N e x t G e n R e v G...

Страница 3: ...9 IV SOFTWARE INSTALLATION 10 1 COMPUTER REQUIREMENTS 10 2 HARDWARE REQUIREMENTS 10 3 DOWNLOAD AND INSTALL SOFTWARE 10 4 INSTALL DATA INTERFACE CABLE 11 V USING THE SOFTWARE 11 1 PHYSICAL CONNECTIONS...

Страница 4: ...Off Inrush Current Elimination ICE Wiring Fault Detection Catastrophic Over Under Voltage Shutdown COUVS with selectable thresholds Under Voltage Event Recorder up to 999 events Over Voltage Event Re...

Страница 5: ...OUT to the machine equipment to be protected Please Note The Next Gen PCS Filter series only provides connectivity and protection for a single phone line connecting the Filter to a phone jack with 2...

Страница 6: ...the Next Gen PCS Filter ii For 120V products and XG PCS 23013 Connect the AC power cords of additional peripherals into the 2 convenience receptacles next to the short output power cord Make sure tha...

Страница 7: ...Monitor will display specific wiring fault information If this occurs contact a licensed electrician to correct the outlet wiring Refer to Section Hardware Next Gen PCS Filter for LCD EVENT MONITOR d...

Страница 8: ...nd troubleshooting i Normal Operation 1 When the Next Gen PCS Filter is plugged into a branch circuit outlet with correct wiring and acceptable line voltage the LCD Event Monitor will cycle through th...

Страница 9: ...round gnd no Ground iii Abnormal Voltage When the magnitude of the branch circuit outlet voltage is not acceptable the Next Gen PCS Filter will disconnect power to its outlets and display the followin...

Страница 10: ...d RJ11 and modular jacks Follow these steps to clear the device memory 1 Unplug the input cord of the Next Gen PCS Filter from the branch circuit outlet 2 Using a paperclip or small screwdriver press...

Страница 11: ...Modem Fax lines connected to the IN and Out RJ 11 modular jacks on the Next Gen PCS Filter Ethernet connections RJ 45 may remain in place Skip this step for XG PCS L630 XG PCS 630 ii Connect the Next...

Страница 12: ...space VGA or higher resolution monitor keyboard mouse CD or DVD drive minimum screen resolution of 1024x768 Microsoft Windows XP Vista 7 8 10 2 Hardware Requirements a For use with enVision enabled pr...

Страница 13: ...Serial Port drivers separately b Manual Installation In the event that the automatic driver installation process was not successful or if no internet connection is available the Data Interface Cable d...

Страница 14: ...oftware and Next Gen Note This process only needs to be done once for each new Data Interface Cable installed on the PC Note This process edits Windows registry values and so may be blocked by MS Wind...

Страница 15: ...mand in the Search box devmgmt msc c Press Enter 2 In the Device Manager expand Ports COM LPT 3 Right click on the entry labeled USB Serial Port COMx and click Properties 4 In the USB Serial Port Prop...

Страница 16: ...nto several operational modes The modes are activated by clicking the corresponding button at the bottom of the software interface Note Some features are only available when used with an enVision PCS...

Страница 17: ...hnical Support 1 800 645 9721 espsurgex com 15 a Multimeter Mode i The Multimeter Mode provides information traditionally acquired from a handheld digital multimeter as well as an overview of the reco...

Страница 18: ...ity events Surge Events SG Overvoltage Events OVrec Undervoltage Events UVrec Power Outage Events PO b Chart Mode i The Chart Mode enables a chart style data logging function of electrical parameters...

Страница 19: ...and provides information about wiring faults and abnormal line voltage ii Use the green On Off button to manually turn the AC outlets on and off Pressing the blue Power Cycle button will result in the...

Страница 20: ...rical Data Mode allows for the retrieval and display of the power quality event data stored in the Next Gen internal memory i Time Stamped Power Quality Event Data Next Gen is able to store and timest...

Страница 21: ...litudes necessary for detection of other surge types may vary Over Voltage Line voltage exceeded the over voltage record threshold Under Voltage Line voltage dropped below the under voltage record thr...

Страница 22: ...ID for saved reports iii Update Limits Sets the voltage thresholds specified by the voltage threshold selection fields Press Default to select factory default limits Note Restore points may not be sp...

Страница 23: ...running the software with elevated permissions right click program shortcut and choose Run As Administrator on Windows Vista 7 8 10 with UAC User Account Control enabled iv Save Saves the COM Port sel...

Страница 24: ...splay the type of voltage condition Use the Communications Software to measure the voltage at the wall receptacle Contact a licensed electrician to troubleshoot the wall receptacle Use the Communicati...

Страница 25: ...elect Troubleshoot Compatibility and follow the wizard Unable to locate or read dictionary file One or more language dictionary files cannot be found in the installation directory Uninstall the softwa...

Страница 26: ...Requirement no load XG PCS 15D XG PCS 20D XG PCS 20815D XG PCS 20820D XG PCS 23013 4 Watts XG PCS L630 XG PCS 630 6 Watts Under Voltage Shutdown 120V Models Adjustable from 80V to 95 V or Disabled Re...

Страница 27: ...mum 64MB of RAM minimum 10MB free hard drive space VGA or higher resolution monitor keyboard mouse CD or DVD drive minimum screen resolution of 1024x768 Microsoft Windows Temperature Range 5C to 35C H...

Отзывы: