ENGLISH
6/12
2.4 Overpressure
If display shows
OUT
you should immediately remove the overpressure
from the instrument. Please also pay attention to pressure peaks, which
are not registered by the instrument.
2.5 MAX/MIN
function
This function is activated by pressing the
key. The instrument will
display the alternating
∧∨
symbols and the current reading. Press
again to show
MAX
maximum pressure reading and the
∧
symbol will
be displayed. Press again to show
MIN
pressure reading and the
∨
symbol will be displayed. Press again to return to the actual pressure
display.
NOTE:
Unit must be switched off to exit the
MAX/MIN
function.
2.6 Data
hold
Pressing the
key freezes the measurement value and the
symbol will appear on the display. Press once more to return to normal
display.
2.7
Selection of pressure units
Press the
key to select required pressure units. Choose between
mbar/bar, PSI, kPa, inHg, mHg, inH
2
O and mH
2
O. This function cannot
be used in connection with the
Data Hold
and
MAX/MIN
functions.
These functions will be indicated in the display by the
∧
,
∨
or
symbols.
Содержание EPM 2021