1
GENERAL SAFETY INFORMATION
7
DR6300 SERIES
www.drexelbrook.com
DR6300-LM ATEX, EDO 2-13-118, Issue 1
Figure 1-3: Ex d[ia] / Ex tD[iaD] nameplate (4...20 mA output)
1
ATEX certification agency code
2
Equipment category (explosive atmosphere - gas)
3
Types of device protection including approved Gas Groups (IIA, IIB or IIC) and temperature classes (T6...T3)
4
Equipment category (explosive atmosphere - dust)
5
Types of device protection (explosive atmosphere - dust)
6
Degree of ingress protection (if fitted with the appropriate cable glands) and maximum surface temperature
7
Maximum voltage in accordance with EN 60079-0
8
Minimum waiting time after power-off before it is safe to open the terminal compartment
9
Cable entry type and size (Aluminium housing: M26×1.5, M20×1.5,
½
NPT or G
½
; Stainless steel housing: M25×1.5,
M20×1.5,
½
NPT or G
½
)