background image

Page 1

Installation Guide

LSP-HD PSU Module

UL Approved

1 Introduction

This document provides installation details for the range LSP-HD PSU Module 

(UL Approved) for Landscan LSP-HD infrared linescanners.

Note

The equipment must be used, maintained and serviced by properly 

trained personnel, capable of following the procedures given in these 

instructions. Safety may be impaired if the system is not used as 

indicated.

It is important to check the equipment with which you have been supplied and 

then read these instructions thoroughly before proceeding with operation.

Содержание 812674

Страница 1: ...LSP HD PSU Module UL Approved Land Instruments International 2018 Installation Guide Publication N 81212 Issue 1 Language English 19 September 2018...

Страница 2: ...sponsibility of the assembler Protective Clothing Face and Eye Protection It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and...

Страница 3: ...gn and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmenta...

Страница 4: ...Installation Guide LSP HD PSU Module UL Approved Contents 1 INTRODUCTION 1 2 SYSTEM OVERVIEW 2 2 1 LSP HD Cable assembly 2 2 2 Schematic Diagram 2 3 SPECIFICATION 3 4 MAINTENANCE 4 5 INSTALLATION DIA...

Страница 5: ...frared linescanners Note The equipment must be used maintained and serviced by properly trained personnel capable of following the procedures given in these instructions Safety may be impaired if the...

Страница 6: ...mbly It is expected that the LSP HD PSU UL Approve will be used with conduit Remove the connector from the LSP HD cable pass through the conduit and connect to the instrument terminals as shown in Dra...

Страница 7: ...4 5 7 1lb in 0 5 0 8 Nm MCB Terminals AWG 18 6 Copper Torque AWG 18 21 21 lb in 2 4 Nm AWG 10 8 25 lb in 2 8 Nm AWG 6 36 lb in 4 0 Nm PE Terminal AWG 22 10 Copper Torque 9lb in 1 0 Nm Notes Max condu...

Страница 8: ...f the accessories and mountings can be cleaned by wiping with a clean cloth moistened with either water or a mild neutral detergent DO NOT use alcohol chemicals or abrasive cleaning products Hoses and...

Страница 9: ...Page 5 Installation Guide LSP HD PSU Module UL Approved 5 Installation Diagrams...

Страница 10: ......

Страница 11: ...SO 2768 740 077 0 2 Earth Live A Mains Power IN 110 240V a c 3 Core 1mm2 MIN Fibre Optic Connection Ethernet Connections B Ethernet or Fibre Optic to I O modules or process control PC Cable CAT5E RJ45...

Страница 12: ......