Health and Safety Information

Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS 

before

 using this product. If there is any instruction which you do not understand, DO 

NOT USE THE PRODUCT.

Safety Signs

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death or 

personal injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in minor or 

moderate injury to the user or users, or result in damage to the product or to property.

NOTE

Indicates a potentially hazardous situation which, if not avoided, could result in damage or loss of data.

Signs and Symbols used on equipment and Documentation

Caution, risk of electric shock.

Caution, attention to possibility of risk of damage to the product, process or surroundings. Refer 

to instruction manual.

Caution, hot surface.

Protective Conductor Terminal.

Observe precautions for handling electrostatic discharge sensitive devices.

Equipment Operation

Use of this instrument in a manner not specified by AMETEK Land may be hazardous. Read 

and 

understand

 the user documentation supplied 

before

 installing and operating the equipment.

The safety of any system incorporating this equipment is the responsibility of the assembler.

Protective Clothing, Face and Eye Protection

It is possible that this equipment is to be installed on, or near to, machinery or equipment operating at 

high temperatures and high pressures. Suitable protective clothing, along with face and eye protection 

must be worn. Refer to the health and safety guidelines for the machinery/equipment before installing 

this product. If in doubt, contact AMETEK Land.

Electrical Power Supply

Before working on the electrical connections, all of the electrical power lines to the equipment must 

be isolated. All the electrical cables and signal cables must be connected exactly as indicated in these 

operating instructions. If in doubt, contact AMETEK Land.

Storage

The instrument should be stored in its packaging, in a dry sheltered area. 

The maximum storage temperature is 10 °C (18 °F) higher than the maximum operating temperature.
The minimum storage temperature is 10 °C (18 °F) lower than the minimum operating temperature.
Refer to the Technical Specification for details of the operating temperature limits.

Unpacking

Check all packages for external signs of damage. Check the contents against the packing note.

Lifting Instructions

Where items are too heavy to be lifted manually, use suitably rated lifting equipment. Refer to the 

Technical Specification for weights. All lifting should be carried out in accordance with local and national 

regulations.

IMPORTANT INFORMATION - PLEASE READ

Содержание 812674

Страница 1: ...LSP HD PSU Module UL Approved Land Instruments International 2018 Installation Guide Publication N 81212 Issue 1 Language English 19 September 2018...

Страница 2: ...sponsibility of the assembler Protective Clothing Face and Eye Protection It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and...

Страница 3: ...gn and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmenta...

Страница 4: ...Installation Guide LSP HD PSU Module UL Approved Contents 1 INTRODUCTION 1 2 SYSTEM OVERVIEW 2 2 1 LSP HD Cable assembly 2 2 2 Schematic Diagram 2 3 SPECIFICATION 3 4 MAINTENANCE 4 5 INSTALLATION DIA...

Страница 5: ...frared linescanners Note The equipment must be used maintained and serviced by properly trained personnel capable of following the procedures given in these instructions Safety may be impaired if the...

Страница 6: ...mbly It is expected that the LSP HD PSU UL Approve will be used with conduit Remove the connector from the LSP HD cable pass through the conduit and connect to the instrument terminals as shown in Dra...

Страница 7: ...4 5 7 1lb in 0 5 0 8 Nm MCB Terminals AWG 18 6 Copper Torque AWG 18 21 21 lb in 2 4 Nm AWG 10 8 25 lb in 2 8 Nm AWG 6 36 lb in 4 0 Nm PE Terminal AWG 22 10 Copper Torque 9lb in 1 0 Nm Notes Max condu...

Страница 8: ...f the accessories and mountings can be cleaned by wiping with a clean cloth moistened with either water or a mild neutral detergent DO NOT use alcohol chemicals or abrasive cleaning products Hoses and...

Страница 9: ...Page 5 Installation Guide LSP HD PSU Module UL Approved 5 Installation Diagrams...

Страница 10: ......

Страница 11: ...SO 2768 740 077 0 2 Earth Live A Mains Power IN 110 240V a c 3 Core 1mm2 MIN Fibre Optic Connection Ethernet Connections B Ethernet or Fibre Optic to I O modules or process control PC Cable CAT5E RJ45...

Страница 12: ......

Отзывы: