background image

 

Figure 3 Fitting the damper

 

 
 

LIGHTING THE AMESTI 

Now the stove is correctly installed it is ready for the first lighting  The AMESTI feature a dual air control system. Air is 
introduced into the fire at the top the firebox as well as the bottom. The top air is operated by the sliding control located 
on the top of the unit. The bottom air control is located on the door of the heater. The bottom air control is used  mainly 
for starting the fire. 

1.

 

Place a few pieces of dry kindling onto some screwed up newspaper and ignite. 

2.

 

As soon as it has caught fire add some larger pieces of wood. Load the wood into the firebox so that the logs are 
placed at right angles to the door opening. Close the door and make sure the top air control is fully opened. 

3.

 

When the fire has well established  coal base add  full size logs  loaded  at right angles to the door  opening  and 
open the top air fully. Adjust the operating temperature of your fire by opening or closing the top control. The 
normal or medium operating position is with the top air open at about half. 

The first few times that the stove is lit the stove paint will give off some smoky fumes as it cures. Don`t panic, once the 
paint has cured this will not re-occur. Keep the room well ventilated until these fumes have cleared. 

 
SLOW BURNING

  

Содержание Nordic 360

Страница 1: ...N OPERATION INSTRUCTION Models Nordic 360 Nordic 380 Nordic 450 KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Manufactured in Chile Jos Miguel Carrera n 6 los Libertadores Colina Santiago Chile Nordic...

Страница 2: ...of the flue pipe must penetrate the roof line by a minimum of 1m or to be in excess of 3m from the roof in a horizontal line or a minimum of 600mm higher than the ridge if within 3m of the ridge If th...

Страница 3: ...leaving space behind it for air circulation Main Flue Stainless steel It extends from the top of the fireplace to the cowl Celing plate Stainless steel Distance from flammable Material Any flammable m...

Страница 4: ...190 355 Note these clearances are for heat sensitive materials Clearance from heat resistant walls e g brick or stone can be 100mm A heat resistant floor e g concrete slab with slate needs no floor p...

Страница 5: ...caught fire add some larger pieces of wood Load the wood into the firebox so that the logs are placed at right angles to the door opening Close the door and make sure the top air control is fully ope...

Страница 6: ...braided rope If it should need replacing fix it in its groove with silicone mastic 4 Fire Bricks The bricks should last many years but if any need replacing they can be placed in position vertically...

Страница 7: ...ifespan that will depend on the intensity of use and the quality of wood used The 1 year warranty will cover the damper against cracking of material and failures of welded joint but not the wear and t...

Отзывы: