Remove the bag and inspect the heat seal. The heat source is from the
bottom, so the heat will go upward on your bag.  The lower two (2) layers
of the bag will most likely be sealed, but you want to make sure that the
upper two (2) layers are also sealed.  This will ensure that if you do seal a
wrinkle in your bag (which is essentially four (4) layers of bag material) it
will definitely be air tight.

NOTE:  Explanation applies to units not equipped with Bi-Active sealing. 

6.

Raise Heat Timer setting one half (1/2) second if the seal is weak or lower
by one half (1/2) second if the seal is good.  Test again by repeating from
step #3 onward.  Adjust Cool Timer so material has time to set before
sealing bar opens, usually about 50% higher than the Heat Timer.
NOTE: To avoid overheating and to extend the life of the Heating Element,
set the Heat Timer to lowest possible setting that will result in a strong
seal.

Before continuing, please read and understand the following 

steps before doing them, as the process will be very fast. 

OPERATING YOUR AMERIVACS 

RETRACTABLE NOZZLE VACUUM SEALER 

Now that your seal parameters are set, let’s start vacuum sealing: 

7.

Keep your Heat and Cool Timer settings just as you determined on the
previous steps.

WARNING:

 Please do not vacuum seal products with liquids only.  Small 

amounts of liquids, powders or other small particles will be sucked by the 
vacuum nozzle.  Make sure your Vacuum Sealer has a Vacuum Filter 
installed on it (by AmeriVacS), or the product will go directly to the vacuum 
pump making the vacuum sealer inoperative. 

NOTE: 

Avoid activating sealer without a bag between the sealing jaws.  

Doing so will make the Retractable Nozzle deteriorate the Rubber seals 
and Teflon between the jaws. 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

 TestEquipmentDepot.com 

Содержание AVS-20

Страница 1: ...OWNER S MANUAL AVS 20 RETRACTABLE NOZZLE VACUUM SEALER 99 Washington Street Melrose MA 02176 800 517 8431 TestEquipmentDepot com Visit us at www TestEquipmentDepot com...

Страница 2: ...unit is made for this higher voltage See serial number tag next to the Power Receptacle of your Sealer to confirm Compressed air set to between 100 and 110 psi NOTE If choosing a portable Air Compres...

Страница 3: ...cable If you ordered the Vacuum Regulator and or Vacuum Filter accessories you will also find these on the back of the Vacuum Sealer and user instructions on the last page of this manual GETTING CONN...

Страница 4: ...The Vacuum Sealer requires a constant air pressure between 100 to 110 psi SETTING THE SEAL PART OF YOUR AMERIVACS RETRACTABLE NOZZLE VACUUM SEALER 1 Turn on your Vacuum Sealer by pressing the main On...

Страница 5: ...ing Element set the Heat Timer to lowest possible setting that will result in a strong seal Before continuing please read and understand the following steps before doing them as the process will be ve...

Страница 6: ...9 Hold bag taut on the sides close to the front of the Pressure bar to avoid any wrinkles in your seal and keeping fingers away from the Sealing Jaws press and hold the Foot Switch When you see that t...

Страница 7: ...the Nozzle Enclosure 3 Lower the Cylinder rods on each sides 4 Re install the Pressure Bar making sure there is an internal tooth washer between the Pressure Bar and the Cylinder Rod and another on to...

Страница 8: ...right element post assembly inward You can use a large flat screwdriver to hold it in the compressed position see photo at right NOTE If you have a 30 or larger sealer repeat above steps for the left...

Страница 9: ...GR 1 Remove old gray or black rubber from machine body and Pressure Bar and any leftover adhesive 2 Remove backing from the one of the new foam rubbers both rubbers provided are the same and press ont...

Страница 10: ...he tip of the nozzle as possible Bag looses its vacuum after time Bag material might be porous Use a bag made for vacuum Do not use channel bags Bag might have been punctured by sharp corner Use thick...

Страница 11: ...99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Отзывы: