FEATURES

1. High performance tube: the AL-1500 uses a single rugged

3CX1500A7/8877 tube.

2. High power gain:

the 3CX1500A7/8877 features high

power gain. As little as 65 watts of drive power will pr
vide 1500 watts of output power.

3. SSB/CW switch: the bias voltage is switched to provide

the best linearity on SSB or the lowest dissipation on CW
operation.

proper operation of the amplifier. The other meter reads
Plate Voltage (HV), Plate Current (IP), Peak RF 

Watts

(PO) and ALC.

7. Operate/Standby Switch: filament and plate voltages are

maintained while allowing the amplifier to be bypassed
for "barefoot" operation.

8.12 Volt Auxiliary Jack: 12 volts at 100 mA is provided for

accessories such as the ATR-15 Antenna tuner.

4. ALC Indicator: the drive level is detected to provide a

control voltage for the exciter. ALC prevents overdriving
of the linear and reduces distortion from excessive drive
power.

5. Vernier Plate and Load Adjustments: both tuning controls

have vernier 6:1 reduction drives for smooth tuning.

6. Two Illuminated Panel Meters: the AL-1500 has two il-

luminated panel meters. The Grid Current meter provides
a continuous reading of grid current and indicates

9. XMT Indicator LED: provides a front panel indication of

proper amplifier keying by the exciter during operation.

10. Grid Overload Circuit: this amplifier has a circuit that

protects the tube from excessive grid current. If 175 mA of
peak grid current is reached the "OPR" LED will no longer
light and the amplifier will go into a bypass condition. This
overload condition can be reset by momentarily putting the
STBY/OPR switch in the STBY position.

Caution: This amplifier must be disconnected from the power
mains before removing the cover. See the warning on page
10.

TECHNICAL SPECIFICATIONS AL-1500

Input:

Circuit type: Pi-network, slug tuned coils Maximum VSWR
at resonance: 

1.3:1 

Minimum 2:1 VSWR bandwidth: 20% of

center frequency Maximum drive power permissable: 100
watts Typical drive for full power output:

65

watts

Metering:
Multimeter: Plate current, plate voltage, drive/ALC, power
output (PEP watts)

Grid: Grid current

ALC: Negative going, 0-20V, adjustable, phono jack

Output:
Circuit type: Pi-L, Pi

/2 

hour continuous carrier: 1500 watts 30 second

continuous carrier: 2500 watts
1/2 hour PEP two-tone test: 2500 watts plus 30 second
PEP two-tone test: 2500 watts plus

Power Supply:
Circuit type: full wave bridge, capacitor input
No load voltage: 3600 V
Full load voltage: 3300 V
Full load current: 1 amp

Regulation: 10% typical
Transformer: 34 lbs., hypersil
Capacitors: 26 mfd total, computer grade
Maximum draw at rated output: 15 amps at 240V AC 50/60 Hz

Tube:
Type:(1) 3CX1500A7/8877
Continuous dissipation: 1500 Watts
Warm-up time: 180 seconds

Efficiency CW: 65% typical

Efficiency SSB (envelope crest): 62%

MARS/WARC: yes, set to nearest highest amateur band

Keying: Requires relay closure or sinking to ground of 

t 12V

DC at 100 mA, phono jack

RF Connectors: S0239

Line Connector: NEMA 6-15P, 240V style

Dimensions: 18

 

1/2

D x 17 W x 10 H

Weight: 77 lbs.

Frequency Coverage: (AL-1500)-1.8, 3.5, 7, 14, 18 and 21

MHz. User modified models cover 24 and 28 MHz. (AL-
1500X/J) Export models-1.8, 3.5,7, 14, 18, 21, 24 and 28
MHz.

Third Order IMD at Rated Output: -36 dB

Содержание AL-1500

Страница 1: ...s 160 through 10 meters The AL 1500 uses a single 3CX1500A7 8877 tube in a class AB2 grounded grid circuit CW FM and RTTY efficiency is improved by shifting the bias deeper into class B The heavy duty power supply and RF components combined with a forced air system utilizing a chimney provide long service life for expensive components The AL 1500 is shipped factory wired for 240 volt 50 60 Hz powe...

Страница 2: ...e fuses fuse caps and the remainder of the chassis screws wrapped in the packing material around the anode connector 4 Please read the GENERAL INFORMATION and SPECIFICATIONS sections before attempting to install the transformer and tube Please note that the tube chimney comes factory installed around the tube socket Go to the INSTALLATION section on page 4 to begin installing the transformer and t...

Страница 3: ...o a bypass condition This overload condition can be reset by momentarily putting the STBY OPR switch in the STBY position Caution This amplifier must be disconnected from the power mains before removing the cover See the warning on page 10 TECHNICAL SPECIFICATIONS AL 1500 Input Circuit type Pi network slug tuned coils Maximum VSWR at resonance 1 3 1 Minimum 2 1 VSWR bandwidth 20 of center frequenc...

Страница 4: ...it board mounted on the front panel side of the filter capacitor board that provides time delay to insure the cathode of the 3CX1500A7 8877 has reached proper operating temperature before high voltage and RF drive power can be applied This board also samples the peak grid current and removes drive if the grid current is excessive The timer portion if this circuit board uses IC1A as a com parator t...

Страница 5: ...RIODIC MAINTENANCE The high voltage present on the plate choke and air variable capacitors attracts dust and dirt out of the air stream It is particularly important that the high voltage areas at the bottom of the plate choke and the insulators on the air variable capacitors be dust free These areas should be inspected every few months if the amplifier is operated in a dusty environment Unplug the...

Страница 6: ...0V operation in Japan Caution Do not use the 220V wiring unless the line voltage is always below 220 VAC The Standard USA voltage is 240 VAC not 220 For 220V operation see Fig 3 follow the first three steps above then follow the steps below 1 Slide the RED boot back on the BRN WHT wire 2 Clip the terminal connector off the wire and slide the RED boot off 3 Remove the restraint from the GRN wire an...

Страница 7: ...ber three 3 lug Refer to the drawing above Use the lug numbers above when referring to both of the Filament connection chart and the Blower connection chart below FILAMENT TRANSFORMER LINE VOLTAGE Th ere are two wires that connect to the terminal lugs which determine the Filament Line Voltage The BLACK wire from the power switch and WHITE wire from rear of the unit connect to different terminal lu...

Страница 8: ...ors 3 Use shielded audio type cable with standard male phono plugs to connect to the RELAY jack on the AL 1500 This jack has positive 12V DC open circuit and supplies 100mA of current when pulled to ground 4 Connect a short ground lead from a good earth and RF ground to the GND terminal 5 The 12V connection on the rear panel provides 12V DC at 100 mA maximum to operate external dial lamps or acces...

Страница 9: ...rupt electrical continuity to the water supply line Install a jumper around any insulating water connections you may find Use heavy copper wire and pipe clamps It is best to ground all equipment to one point at the operating position and then ground this point as described above TUNING INSTRUCTIONS Proper tuning of a grounded grid linear amplifier is best accomplished with an understanding of what...

Страница 10: ... It should be 75 mA Place the CW SSB switch in the SSB position Plate current should now read 250 mA Return the CW SSB switch to the CW position Note The no drive currents will vary up to 25 due to component and line voltage tolerences 8 Apply only enough drive to indicate a grid current of 50 mA or an Ip of no more than 500mA Tune the PLATE control for maximum output power or grid current It is n...

Страница 11: ...OCEDURE 1 Place the SSB CW switch in the SSB position 2 Adjust the exciter gain control to permit voice peaks to reach the same value the peak output meter read on CW when fully loaded The plate and grid currents should remain well below 50 of the CW values during normal modulation SSTV FM RTTY PACKET AMTOR The plate current should be limited to 800 mA maximum The grid current should be limited to...