6 //
8
10719 P/N: 16168 Rev C
Rubex Stair Lift Owner’s Manual | www.Ameriglide.com | 866-378-6648
TROUBLE SHOOTING YOUR LIFT
These tips might save you a service call. Make sure you remove power from the lift
before attempting any of the following items.
•
Lift not running, steel cable not tight
A “slack cable” safety device stops the lift from running if any slack is sensed in
the cable. To reset the device, do the following: Remove the square metal plate
cover on the side of the lift facing uphill. Insert the handcrank tube onto the pulley
and turn clockwise until the cable is fully wound tightly on the drum and the lift
begins coming up the track. A loud click will occur indicating the safety device has
been reset. The lift should now run.
If the lift is not all the way at the bottom of the track, an alternative method for
resetting the slack cable device may be used. Half way between the lift and top
of the track, grasp the steel cable and lift it straight up in the air (as if you were
pulling on a bow string) until you are holding the weight of the lift. Slowly lower
the cable back down to the track, the lift will travel down the track and the cable
will now be tight.
•
Lift all the way at top of track- unit won’t run
The lift hit the final limit switch-meaning it has run too far up. Remove the square
metal plate cover on the side of the lift facing uphill. Insert the handcrank tube
onto the pulley and turn counter-clockwise 4-5 turns until the lift moves down the
track about 1
"
. Slide the final limit actuator (metal tab sticking up off the track)
down until it touches the lift. The lift should now run. Lower the top switch cam
about
1
/
2
"
to keep problem from recurring.
Содержание RUBEX