19

TROUBLESHOOTING GUIDELINES

TROUBLE SHOOTING

Please check guidelines below.  For your safety, water heater service should be performed only by a qualified service technician.  

Read the GENERAL SAFETY INFORMATION section first.

INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL

PROBLEM

SOLUTION

Ignition/flame failure.

6

The water heater has reached the

maximum number of retries and is

currently locked out for one hour.

Cycle the power to the water heater

off and on to reset.

Service Note:

The resistance (ohms) of a hot surface

ignitor will increase over time. If the

resistance at room temperature is near

18.8 ohms - consider replacing the ignitor

as a preventative measure.

Self diagnostic tests have found a problem 1. Turn the power off for 10-20 seconds then on again to

7

with the gas valve driver circuit, internal

clear these error codes.

microprocessor, or other internal circuits. 2. If any of these error codes persist or cannot be cleared-

replace the Intelli-Vent™ control.

8

9

Flame signal has been sensed out of

1. Turn the power off for 10-20 seconds and then on again

10

proper sequence.

to clear this error code.

2. Replace the Intelli-Vent™ control if this error code persists.

Water temperature in the tank has

1. Turn the power off for 10-20 seconds then on again

11 exceeded 195°F (91°C) and has

to clear this error code.

activated the ECO.

2.  Replace the Intelli-Vent™ if the error code persists.

The self diagnostic check detected one 

12

13

14

or both of the temperature adjust buttons

are stuck.

The self diagnostic test has detected the

water temperature sensor (thermistor) is

either open or shorted.

2. Replace the Intelli-Vent™ control if this error code persist.

#       LED STATUS

WA

TE

RH

EA

TE

RC

ONTROL

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

B  C  D  E  F

1. Press and release temperature adjust buttons. If above 

 action does not clear error, control will continue to regulate 

  water temperature at last setting. However, settings will no 

  longer be adjustable - the control should be replaced.
1. Turn power off for 10-20 seconds then on again to

 clear this error code.

4. Ensure the flame sensor is clean - use ultra fine steel

  wool or Scotch-Brite™ pad to clean flame sensor.
5. Ensure the hot surface ignitor is positioned to provide

 consistent ignition.
6. Check for any cracks in ignitor assembly ceramic

  insulators - replace ignitor assembly if damaged.
7. Check resistance of ignitor at room temperature (77ºF)

  (25°C) at the plug end. Replace ignitor if resistance is

  not within 11.5 and 18.8 ohms at room temperature.
8. Ensure correct size of vent pipe (2”, 3”, 4”) was used per 

  installation manual for vent length. Using larger pipe than required 

  may cause excessive air turbulance in combustion chamber.

1. Turn off power to the water heater.  

2. Insure black resistor wire is not cut, missing, and is installed 

  between pins 3 & 4 of ignitor assembly plug. Replace ignitor 

 assembly if damaged or defective.  

3. Unplug ignitor assembly plug from control. Check resistance 

  of black resistor wire between pins 3 & 4 with an ohm meter. 

  3.1 If reading taken is less than 2000 (5000 for date code 0617 

  through 0709) or more than 1.7 million ohms, replace ignitor 

 assembly. 3.2 If reading taken is between 2000 (5000 for date 

 code 0617 through 0709) and 1.7 million ohms, replace 

  Intelli- Vent™ control.  

Service Note: 

Raised ridges on ignitor assembly plug identify 

#1, #2, and #3 pins.  The four-digit date code can be found on 

side of the controller.

Self-diagnostic test found a problem with black 

resistor wire on the ignitor assembly plug; resistor 

wire is open or shorted.

Service Note: 

To perform this test ohm meter 

used must be capable of reading up to 2,000,000 

ohms. Unless ohm meter used has an auto-range 

feature resistance should be checked twice. First 

reading will be taken using an ohms scale above 

1,700,000 ohms. Second reading is taken using 

ohms scale just above 2,000 or 5,000 ohms.

2. Low supply voltage - should be 115 -125 VAC.
3. Ensure flame sensor is making good contact with burner

 flame, ensure flame is steady see #8 below.

1. Gas supply is turned off-pressure too low. Ensure supply and 

 manifold gas pressures are within requirements in installation 

  manual. Manifold gas pressure is non-adjustable if pressure is 

  off by more than 0.3” W.C. (75 Pa) replace Intelli-Vent™ control.

Содержание BBCN375T754NV 100 Series

Страница 1: ...AL ULTRA LOW NOx GAS WATER HEATER Glass Lined Tank type Water Heater INSTALLATION OPERATION SERVICE MAINTENANCE LIMITED WARRANTY CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE T...

Страница 2: ...Canada Current edition of the Installation Code CAN CSA B149 1 and the Canadian Electrical Code CSA C22 1 These are available from Canadian Standards Association 8501 East Pleasant Valley Road Clevel...

Страница 3: ...r and Igniter 12 Checking Gas Input 12 Vent System 12 Blower Maintenance 13 Relief Valve 13 Hot Water Odor 13 Winter Protection 13 Replacement Parts 13 PREVENTIVE MAINTENANCE 13 14 Procedure for Perio...

Страница 4: ...gas in excess of the safe limits This could result in serious injury or death Contact your local gas supplier for any specific changes that may be required in your area Upon completion of derating of...

Страница 5: ...THROUGH THE CHIMNEY OR VENT PIPE The venting of the water heater should be inspected by a qualified service technician at the time of installation and periodically thereafter to ensure a down draft c...

Страница 6: ...t of the vent system are exposed to ambient temperatures below 35 degrees F 2 degrees C it must be insulated to prevent condensation Do not connect the heater to a common vent or chimney with solid fu...

Страница 7: ...E LOCATION TO AVOID SCALDING OR WATER DAMAGE THIS LINE MUST NOT BE REDUCED FROM THE SIZE OF THE VALVE OUTLET AND MUST NOT CONTAIN VALVES RESTRICTIONS NOR SHOULD IT BE LOCATED IN FREEZING AREAS DO NOT...

Страница 8: ...having jurisdiction AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION If any of the original wire as supplied with the appliance must be replaced use only t...

Страница 9: ...matic gas valve while heater is operating TABLE 5 Type of Gas Input Manifold Pressure Natural 75 100 Btu hr 22 KW hr 4 0 in W C 1 12 kPa OPERATION It is recommended that a qualified person perform the...

Страница 10: ...as been under water OPERATING INSTRUCTIONS A Set thermostat to the lowest setting B Turn off all the electric power to the appliance if service is to be performed TO TURN OFF GAS TO APPLIANCE BEFORE O...

Страница 11: ...akage corrosion and other deficiencies which could cause an unsafe condition 3 So far as is practical close all building doors and windows and all doors between the space in which the water heater s c...

Страница 12: ...rn doors windows exhaust fans fireplace dampers and any other gas burning appliance to their previous conditions of use 7 If improper venting is observed during any of the above tests the venting syst...

Страница 13: ...anode as necessary to maintain corrosion protection For further information contact your dealer WINTER PROTECTION In regions where freezing weather is encountered all water must be drained from unit...

Страница 14: ...the Flo Jug kit This screw is to be installed in the vent hole when Flo Jug is not in use Remove drain valve from heater and insert a 3 4 x 4 nipple Connect and clamp 1 I D x 3 hose to Flo Jug and hea...

Страница 15: ...idence of poor vent action Possible causes are too long a vent pipe or improper chimney operation 3 If the leakage is from the temperature and pressure relief valve or its discharge pipe it may repres...

Страница 16: ...information and tables may serve to answer your question about a problem that you are having without having to call a service agent For your safety water heater service should be performed only by a q...

Страница 17: ...a qualified person for service 3 Thermostat problems A Thermostat set too low Set temperature control higher B Thermostat or ECO defective Replace gas control valve thermostat C High limit control ci...

Страница 18: ...control does not energize the blower replace the Intelli Vent control If the blower fails to Blower may run continuously in start when energized replace the blower assembly this condition 2 Ensure the...

Страница 19: ...ff for 10 20 seconds then on again to clear this error code 4 Ensure the flame sensor is clean use ultra fine steel wool or Scotch Brite pad to clean flame sensor 5 Ensure the hot surface ignitor is p...

Страница 20: ...in tolerance 1 Ensure air pressure switch hose is not kinked or clogged ensure the blower housing is clear of any condensation 2 Check vent temperature limit switch if it is determined that the vent t...

Страница 21: ...21 NOTES...

Страница 22: ...22 NOTES...

Страница 23: ...hod of controlling thermal expansion is also installed at the heater s and operational at all times The relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES U...

Страница 24: ...nson City TN 37605 Phone 800 456 9805 Fax 800 999 5210 www americanwaterheater com Copyright 2012 American Water Heater Company All rights reserved www americanwaterheater com American Water Heater Jo...

Отзывы: