Multi Tone Generator

Contact 

Information

Operation

Specifications

Operation

Use with SiteSync IQ

®

 System Controllers

The tone generator can also be used in conjunction with the SiteSync IQ System Controller to schedule 

the triggering of tones. This can be done by hardwiring the tone generator to the SiteSync IQ System 

Controller or wirelessly through the SiteSync IQ transmitter.

The unit can be triggered by wiring the desired T1-T4 combinations to the NO terminal of one of the six 

bell circuits located on the back of the SiteSync IQ system controller. The COM terminal of the system 

controller bell circuit should then be connected to the C terminal (Tone Selection Common). The user 

can now set up circuit events on the SiteSync IQ system controller which control when and how long 

the desired tone is triggered off and on.

n

Note:

  See the SiteSync IQ Wireless Installation Manual before installation. Also, verify that the 

system controller you have has the bell circuit option.

REAR OF SY

STEM C

ONTR

OLLER

COM

NO

NC

NC

COM

NO

NO

COM

NO

COM

COM

NO

NO

COM

NO

COM

NO

COM

CLOCK 1

CLOCK 2

BELL 1

BELL 2

BELL 3

BELL 4

BELL 5

BELL 6

GAIN

T1

T2

T3

T4

PA/AMP

IN

COM

Red (+)

Blk (-)

COM

COM

SPKR

SPKR

AUDIO IN

AUDIO OUT

(+)

(-)

12VDC

Multi-T

one Generator

(500 mA max)

1-800-328-8996      www

.atsclock.com

Wiring Diagram

Содержание H004291A

Страница 1: ...Installation and Operation Manual Part H004464 Rev 1 June 2010 Wired Tone Generator...

Страница 2: ...ipment such as an AllSync Master or SiteSync IQ System Controller refer to the appropriate manual and instruction documentation before attempting setup For Masters Signal Programmers and System Contro...

Страница 3: ...Specifications 5 Operation 6 Use with SiteSync IQ Wired System Controller 7 Use with AllSync Wired Master 8 Use with YMP YBP Clock Signal Programmer 9 Contact Information and Customer Support 10 Amer...

Страница 4: ...T1 T2 T3 T4 8 OHM P A AMP TONE SELECT PWR MOD COM COM SPKR SPKR AUDIO IN AUDIO OUT 12VDC Multi Tone Generator 500 mA max 1 800 328 8996 www atsclock com 5 60 5 23 4 60 4 60 3 50 2 30 2 80 The tone gen...

Страница 5: ...T4 four dry contact inputs for tone selection The Audio In input allows normal background audio to play Pre empted by tone selection inputs T1 T4 Steady tones and Whoop last for the duration of the co...

Страница 6: ...ble see below lists which T1 through T4 combinations are needed for each desired tone The Power Audio Input and Audio Outputs are also connected and labeled on the terminal block Apply a contact closu...

Страница 7: ...IQ system controller The COM terminal of the system controller bell circuit should then be connected to the C terminal Tone Selection Common The user can now set up circuit events on the SiteSync IQ...

Страница 8: ...M NO COM CLOCK 1 CLOCK 2 BELL 1 BELL 2 BELL 3 BELL 4 BELL 5 BELL 6 GAIN T1 T2 T3 T4 PA AMP IN COM Red Blk COM COM SPKR SPKR AUDIO IN AUDIO OUT 12VDC Multi Tone Generator 500 mA max 1 800 328 8996 www...

Страница 9: ...tone generator to the master nNote See the AllSync Installation Manual before installation Also verify that the master you have has the bell circuit option Bottom of the AllSync Master NO CLOCK1 CLOCK...

Страница 10: ...ibed in the YMP Plus and YBP Plus Installation Manuals nNote See the YMP Plus or YBP Plus Installation Manual before installation Also verify that the master you have has the circuit option CIRCUIT 1...

Страница 11: ...ion Specifications For additional support on product setup on the tone generator or on any of the American Time products please call or visit our web site American Time 140 3rd St So PO Box 707 Dassel...

Отзывы: