Multi Tone Generator

Contact 

Information

Operation

Specifications

Specifications

Output Signal Specifications

Rated Output:

 ................ Adjustable from 0-1.15 volt P-P

Load Impedance:

 .......... 600 ohms or higher

Power Requirements:

 ... 12-15vdc, 1 amp maximum; plug-in power module included

Controls:

 ........................ Gain control - Screwdriver adjustment on the front panel

Inputs:

 ........................... T1-T4 four dry contact inputs for tone selection. The Audio In input  

 

....................................... allows normal background audio to play. Pre-empted by tone selection inputs  

....................................... T1-T4.

 • Steady tones and Whoop last for the duration of the    

   contact input.
 • Pulsed tones are 0.4 seconds ON and 0.4 seconds OFF  

    with a one second break before repeating.
 • A two pulse tone repeats every 2.5 seconds for the    

    duration of contact input.
 • A three pulse tone repeats every 3.25 seconds for the   

   duration of the contact input.
 • The Chime sounds once when the contact is closed and  

 

   again when the contact is opened.

Содержание H004291A

Страница 1: ...Installation and Operation Manual Part H004464 Rev 1 June 2010 Wired Tone Generator...

Страница 2: ...ipment such as an AllSync Master or SiteSync IQ System Controller refer to the appropriate manual and instruction documentation before attempting setup For Masters Signal Programmers and System Contro...

Страница 3: ...Specifications 5 Operation 6 Use with SiteSync IQ Wired System Controller 7 Use with AllSync Wired Master 8 Use with YMP YBP Clock Signal Programmer 9 Contact Information and Customer Support 10 Amer...

Страница 4: ...T1 T2 T3 T4 8 OHM P A AMP TONE SELECT PWR MOD COM COM SPKR SPKR AUDIO IN AUDIO OUT 12VDC Multi Tone Generator 500 mA max 1 800 328 8996 www atsclock com 5 60 5 23 4 60 4 60 3 50 2 30 2 80 The tone gen...

Страница 5: ...T4 four dry contact inputs for tone selection The Audio In input allows normal background audio to play Pre empted by tone selection inputs T1 T4 Steady tones and Whoop last for the duration of the co...

Страница 6: ...ble see below lists which T1 through T4 combinations are needed for each desired tone The Power Audio Input and Audio Outputs are also connected and labeled on the terminal block Apply a contact closu...

Страница 7: ...IQ system controller The COM terminal of the system controller bell circuit should then be connected to the C terminal Tone Selection Common The user can now set up circuit events on the SiteSync IQ...

Страница 8: ...M NO COM CLOCK 1 CLOCK 2 BELL 1 BELL 2 BELL 3 BELL 4 BELL 5 BELL 6 GAIN T1 T2 T3 T4 PA AMP IN COM Red Blk COM COM SPKR SPKR AUDIO IN AUDIO OUT 12VDC Multi Tone Generator 500 mA max 1 800 328 8996 www...

Страница 9: ...tone generator to the master nNote See the AllSync Installation Manual before installation Also verify that the master you have has the bell circuit option Bottom of the AllSync Master NO CLOCK1 CLOCK...

Страница 10: ...ibed in the YMP Plus and YBP Plus Installation Manuals nNote See the YMP Plus or YBP Plus Installation Manual before installation Also verify that the master you have has the circuit option CIRCUIT 1...

Страница 11: ...ion Specifications For additional support on product setup on the tone generator or on any of the American Time products please call or visit our web site American Time 140 3rd St So PO Box 707 Dassel...

Отзывы: