background image

21

© American Time

AllSync Plus Clock Installation 

& Operation Manual

Glossary

Appendix B  LED 

Illumination

Appendix A 

Specifications

Tr

oubleshooting

General 

Operation

Installation

Intr
oduction

AllSync Plus Clock Specifications

Page 2 of 2

At American Time, we continually strive to improve our products to meet our customers’ needs and to provide the best possible value.  The above specifications 

are believed to be correct, are subject to change without notice and may otherwise vary from the above. Please call if you need verification of any specifications or 

the suitability of a particular product for a particular application. 

PS03010 Rev H

SPECIFICATIONS

•  24vac/60 Hz or 120vac/60 Hz

•  Current draw:  24vac, 1 watt, .043 amps
   

120vac, 3 watts, .028 amps

GENERAL

Types of secondary clocks compatible with AllSync Plus:
Cincinnati 

WS*, *D-8, *D-10, *D-12 Series 

Dukane 

24SS* Series, 240* Series

Edwards 

*010 & *012 Series

Faraday 

2315*, 2316*, 2335*, 2336*, 2380*, 2382*, 2310*, 2320*, 2330*, 2313*, 2314*, 2333*, 

 

1310 through 1431 Series and 2420* through 2431* Series

Honeywell 

ST402A* Series

Lathem 

Type SS* Series

National Time  

*EX-HH and *EX-LL Series

Simplex

®

 & IBM 

77* Series, 82* Series, 2310 – 92* Series, 6310 – 92* Series

*Indicates more numbers before or after.

ORDERING INFORMATION

Part # 

Description 

U45BHAA?04   10" Rd Flush, Black Sand  120vac
U45BHBA?04 

10" Rd Flush, Black Sand  24vac

U55BHAA?04    12" Rd Flush, Black Sand  120vac
U55GHAA?04 

12" Rd Flush, Steel Gray  120vac

U55BHBA?04 

12" Rd Flush, Black Sand  24vac

U55GHBA?04 

12" Rd Flush, Steel Gray  24vac

U58BHAA?04    12" Sq Flush, Black Sand  120vac
U58BHBA?04 

12" Sq Flush, Black Sand  24vac

U65BHAA?04 

15" Rd Flush, Black Sand  120vac

U65BHBA?04 

15" Rd Flush, Black Sand  24vac

Note: 

Replace the ? in the part number with the number from the list below that will correspond with the system you’re replacing. 
New flush mount installations require backboxes.
0 = Faraday  

1 = National 

5 = Simplex

®

 

6 = Cincinnati/Edwards  

7 = 2-hook 

8 = Setco 

9 = R&H (keyhole)

For a plexiglass crystal, replace the BH or GH in the part number with BG or GG.

Maximum operating voltage:  24vac setting = 40vac
 

120vac setting = 150vac

Minimum operating voltage:  24vac setting = 15vac
 

120vac setting = 50vac

BEZEL FINISHES

Steel Gray=GH
Smooth satin 
finish 12" round 
only

Black Sand=BH
Matte finish

OUTSIDE DIMENSIONS
Round
“A” Dimensions:

  

 

11

1

4

" for 10" clocks

13

1

4

" for 12" clocks

16" for 15" clocks  
 

“B” Dimensions: 

1

5

8

" for 10", 12" & 15" clocks

OUTSIDE DIMENSIONS
Square (12" only)
“A” Dimensions:

  

 

12

5

8

" for 12" clocks  

 

“B” Dimensions: 

1

1

4

" for 12" clocks

Steel 

surface mount

Steel 

flush mount

A

A

B

B

Flush mount 

steel square

Surface mount 

steel square

A

A

B

B

Содержание AllSync Plus

Страница 1: ...Installation and Operation Manual Part P000018 Rev 3 January 2013 AllSync Plus Clocks...

Страница 2: ...American Time 2 AllSync Plus Clock Installation Operation Manual American Time 140 3rd Street South PO Box 707 Dassel MN 55325 0707 Phone 800 328 8996 Fax 800 789 1882 atsclock com...

Страница 3: ...tine 14 General Operation 16 AllSync Plus accuracy 16 Movement corrections 16 Start Up Example Operation 17 Troubleshooting 18 Appendix A AllSync Plus Clock Specifications 20 AllSync Plus Flush Metal...

Страница 4: ...aster must be installed by qualified persons in conformance with applicable national and local electrical codes Improper installation of this equipment can result in lethal electrical shock and fire D...

Страница 5: ...ction Introduction The AllSync Plus Clock Manual explains how to install AllSync Plus Clocks and understand their operation The American Time AllSync Plus clock is the second generation of the AllSync...

Страница 6: ...re completing all wiring connections The AllSync Plus clock can run off either 24vac 60 Hz or 120vac 60 Hz To change between the two different supply voltages two jumpers must be set inside each clock...

Страница 7: ...connections between flying leads and wiring inside electrical box a Black wire should be connected to hot run wire from the master b Red wire should be connected to the correction line from the master...

Страница 8: ...t 6 Make connection between clock and wall wiring using attached four conductor mating connectors 7 Bundle wires inside clock bezel 8 Slide keyhole hanger over ribbed hanging stem on mounting bracket...

Страница 9: ...ved wire nuts make connections between flying leads and wiring inside electrical box a Black wire should be connected to hot run wire from the master b Red wire should be connected to the correction l...

Страница 10: ...meet UL clock listing 1 Remove the AllSync Plus clocks double dial ring wiring harnesses backbox plate and plastic bushings from the packaging 2 Insert plastic bushing into box plate to protect wires...

Страница 11: ...ite wire should be connected to the neutral line d Green wire should be connected to earth ground Note All wiring connections should be made in accordance to local and national electrical codes 7 Atta...

Страница 12: ...pproved wire nuts make connections between flying leads and wiring inside electrical box a Black wire should be connected to hot run wire from the master b Red wire should be connected to the correcti...

Страница 13: ...late from clock by removing acorn nuts at the base of the clock Pull wall wiring through plate hole and attach to electrical box 3 Using UL approved wire nuts make connections between flying leads and...

Страница 14: ...turn solid red Note The solid red LED indicates the clock circuit board has not received a 12 hour correction 4 The clock will stop rapid advancement sometime between 12 50 and 1 15 as seen on the clo...

Страница 15: ...15 American Time AllSync Plus Clock Installation Operation Manual Glossary Appendix B LED Illumination Appendix A Specifications Troubleshooting General Operation Installation Introduction User Notes...

Страница 16: ...er s time After approximately 2 days the AllSync Plus clock should be 1 second to the master system clock Movement corrections The AllSync Plus clock has two primary yet completely separate parts the...

Страница 17: ...s applied to clock at 9 am actual time with the clock displaying 3 o clock The clock microcontroller starts counting at 12 50 25 minutes 25 minutes after power has been applied clock face matches micr...

Страница 18: ...style correction with different hourly correction then if needed change clock protocol back refer to your master clock instructions for setting clock protocol AllSync Plus Clock Synchronized to the co...

Страница 19: ...ster clock is wired and operating correctly o Verify wiring to clock check voltage using voltmeter o Contact American Time Technical support at 800 328 8996 Note You may damage clock by changing power...

Страница 20: ...of backup run power without the use of batteries If a power outage should last longer than 15 minutes the clock will synchronize to the master clock at the hourly and 12 hour correction cycles Correct...

Страница 21: ...re numbers before or after ORDERING INFORMATION Part Description U45BHAA 04 10 Rd Flush Black Sand 120vac U45BHBA 04 10 Rd Flush Black Sand 24vac U55BHAA 04 12 Rd Flush Black Sand 120vac U55GHAA 04 12...

Страница 22: ...rs on the circuit board can change the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac This clock provides 15 minutes of backup run power without the use of batteries If a p...

Страница 23: ...ries Edwards 010 012 Series Faraday 2315 2316 2335 2336 2380 2382 2310 2320 2330 2313 2314 2333 1310 through 1431 Series and 2420 through 2431 Series Honeywell ST402A Series Lathem Type SS Series Nati...

Страница 24: ...lock will synchronize to the master clock at the hourly and 12 hour correction cycles Correction Signals Works on Hourly Correction 28 75 35 seconds starting at the 59th minute and 30th second 12 hour...

Страница 25: ...ac 120vac setting 150vac Minimum operating voltage 24vac setting 15vac 120vac setting 50vac BEZEL FINISHES Steel Gray GH Smooth satin finish 12 round only Black Sand BH Matte finish OUTSIDE DIMENSIONS...

Страница 26: ...changing the placement of 2 small jumpers on the circuit board can change the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac This clock provides 15 minutes of backup run po...

Страница 27: ...ry clocks compatible with AllSync Plus American Time X Series Standard Electric CR GRC 109106 through 109155 Series and 105047 through 105066 Series Indicates more numbers before or after SPECIFICATIO...

Страница 28: ...ge the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac This clock provides 15 minutes of backup run power without the use of batteries If a power outage should last longer t...

Страница 29: ...EX LL Series Simplex IBM 77 Series 82 Series 2310 92 Series 6310 92 Series Indicates more numbers before or after ORDERING INFORMATION Part Description U64BAAA304 15 Rd Surface 120vac U64BABA304 15 Rd...

Страница 30: ...ircuit board can change the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac This clock provides 15 minutes of backup run power without the use of batteries If a power outage...

Страница 31: ...ace 24vac U64BHAA404 15 Rd Surface 120vac U64BHBA404 15 Rd Surface 24vac Notes Replace the BH Black Sand in the part with GH for a Steel Gray case 10 all square available in Black Sand only For a plex...

Страница 32: ...ement of 2 small jumpers on the circuit board can change the voltage required to run this clock from 120vac to 24vac or 24vac to 120vac This clock provides 15 minutes of backup run power without the u...

Страница 33: ...BA304 12 Rd Surface 24vac U53BAAA204 12 Rd Double dial wall 120vac U53BABA204 12 Rd Double dial wall 24vac U52BAAA204 12 Rd Double dial ceiling 120vac U52BABA204 12 Rd Double dial ceiling 24vac Note D...

Страница 34: ...Technical support for assistance at 800 328 8996 Alternating Red and Green 0 5 sec Red 0 5 sec Green AllSync Plus circuit board receiving correction signal from master Both colors OFF 1 sec At the top...

Страница 35: ...ch 1 OFF Or 4 1 sec OFF 5 1 sec Green DIP Switch 2 ON or Red DIP Switch 2 OFF Or 6 1 sec OFF 7 1 sec Green DIP Switch 3 ON or Red DIP Switch 3 OFF Or 8 1 sec OFF 9 1 sec Green DIP Switch 4 ON or Red D...

Страница 36: ...nc Plus operational state in which power is applied for the first time or after the clock has not had power for a sufficient amount of time to drain it to the point it resets its internal processor LE...

Отзывы: