. 3 & 7
SERVICE
CHECK DRAIN CONNECTIONS
1
2
3
Operate Lift Rod and fill lavatory with water. Check that
DRAIN STOPPER
(1)
makes a good seal and retains water
in lavatory. Adjust stopper height by repositioning Lift
Rod
(2)
and tightening Thumbscrew
(3)
.
Release DRAIN STOPPER
(1)
and check all drain
connections and "P" trap for leaks. Tighten if necessary.
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Pull out INDEX CAP
(1)
and remove
HANDLE SCREW
(2)
.
Pull off HANDLE
(3)
and unscrew
ESCUTCHEON BASE
(4)
.
Remove SPRING CLIP
(6)
.
Lift STOP WASHER
(5)
, turn 90
p
and replace.
Replace SPRING CLIP
(6)
.
Reinstall ESCUTCHEON
(4)
and HANDLE
ASSEMBLY.
If spout drips, operate handles several times
from OFF to ON position. Do not force - handles
turn only 90
p
.
90
p
5
6
4
3
2
1
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
EverClean™ Finish Care Instructions