background image

Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

Thread TEE BODY 

(4)

 to SPOUT SHANK 

(5)

.

Thread HOSE CONNECTOR 

(6, 6A)

 to VALVE CONNECTIONS 

(7, 7A)

.

8

Connect water supply to VALVE BODIES 

(1,1A)

 with 1/2" IPS FLEXIBLE

SUPPLIES 

(2)

 or 3/8" O.D. BULL-NOSE RISERS 

(3)

. Use

adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.

MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED

AND MUST BE PURCHASED SEPARATELY.

HOT

COLD

FERRULE

COMPRESSION

NUT

COUPLING

NUT

FLEXIBLE

SUPPLIES

1

1A

3/8 O.D.

BULL-NOSE

RISERS

1/2" PIPE THREAD

3/8 COMPRESSION

CONNECTION

2

3

4

5

2

7

6

6A

7A

Thread CABLE CONNECTOR 

(1) 

clockwise

onto DRAIN BODY CONNECTION 

(2)

 and

hand tighten. 

Fig.

 

A.

Your new POP-UP DRAIN installation is
now complete. 

Fig.

 

B.

Note: 

Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

 

B.

Fig.

 

A.

ATTACH CABLE CONNECTOR

6

2

1

Operate LIFT KNOB 

(1)

 to verify that STOPPER 

(2) 

opens and

closes.

Note: 

If STOPPER 

(2)

 does not open and close properly then refer

to the “troubleshooting section” of these instructions.

CHECK OPERATION OF POP-UP

7

1-1/4” O.D.

Fig.

 

B.

WASTE

OUTLET

1

M 9 6 8 6 7 2   R e v .   1 . 1

Содержание Symphony 4508S

Страница 1: ...ntil snug against internal stop If necessary adjust LOCKNUT 11 1 1A M968672 Rev 1 1 4508 4508S Certified to comply with ANSI A112 18 1 Installation Instructions SYMPHONY Spread Lavatory Faucet with Sp...

Страница 2: ...COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A 2 REAR OF SINK 4 5 6 3 1 SINK DRAIN HOLE FLAT SIDE OF GASKET MUST FACE DOWN 1 2 Fig A 2 1 FLAT SIDE OF GRAY LOCKNUT MUST FACE UP INSTA...

Страница 3: ...ER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY HOT COLD FERRULE COMPRESSION NUT COUPLING NUT FLEXIBLE SUPPLIES 1 1A 3 8 O D BU...

Страница 4: ...rn only 90 1 4 3 5 UNTHREAD HANDLE ASSEMBLY 1 2 4 5 3 TOP SPLINE END DOWN Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 without a spline is facing up Fig A Tighten STEM SCREW 3 to s...

Страница 5: ...p fully or sink drains too slowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by li...

Страница 6: ...Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loo...

Страница 7: ...tools METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE UNTHREAD FLANGE STOPPER WHEN DRAIN IS REMOVED FROM ABOVE SINK WHEN DRAIN I...

Отзывы: