M968852 Rev.1.3
6
TEST INSTALLED FAUCET
7
Turn HANDLES to "off" position.
Remove AERATOR
(1)
using TOOL
(2)
supplied.
Check all drain connections for leaks.
Turn handles to OFF position. Replace AERATOR
(1)
.
Turn hot and cold water supplies on. Operate
both HANDLES to flush water lines thoroughly.
Check spout connections for leaks.
TO REMOVE
HANDLE
90˚
5
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE
(1)
to remove
HANDLE ASSEMBLY
(2)
from ESCUTCHEON BASE
(3)
.
Use a flat blade screw driver to remove SPRING CLIP
(4)
.
Lift STOP WASHER
(5)
, turn 90˚ and replace.
Replace SPRING CLIP
(4)
.
Reinstall HANDLE ASSEMBLY
(2)
.
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
SERVICE
3
2
5
1
1
4
2
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: