background image

Installation InstructionsIn

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

(In Toronto Area only: 1-905-3061093)

Certified to comply with ASME A112.19.2M

© 2008 AS America, Inc.

NOTE TO INSTALLER: Please give this manual to the customer after installation.

SELECTRONIC™

PROXIMITY URINAL FLUSH VALVE

0.5 & 1.0 GPF

Exposed Flushometer
for 3/4

"

 Top Spud Urinals

CLOG RESISTANT

• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL

• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and flush valves.
• Range can be adjusted manually or with optional remote control.
• Sensor Features Low Battery Indicator.

M968567 Rev. 1.2

6063.510
6063.505

6063.051
6063.101

MODEL NUMBERS

To learn more about American Standard Faucets visit our website at: 

www.americanstandard-us.com

or U.S. customer's e-mail us at: 

[email protected]

For Parts, Service, Warranty or other Assistance, 

please call

 

1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-3061093)

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Содержание Selectronic Proximity Urinal Flush Valve 6063.051

Страница 1: ...lve prevents clogging and reduces maintenance ONE SENSOR FITS ALL Only 1 sensor for entire Selectronic line of faucets urinals and flush valves Range can be adjusted manually or with optional remote c...

Страница 2: ...RODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE CARE INSTRUCTIONS I n s t a l l a t i o n I n s t r u c t i o n s I n s t a l l a t i o n I n s t r u c t i o n...

Страница 3: ...ents that are subject to normal wear These components should be checked on a regular basis and replaced as needed to maintain the valve s performance IMPORTANT All plumbing must be installed in accord...

Страница 4: ...plied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement ta...

Страница 5: ...Fig 6 4 1 4 Fig 7a Fig 7c Fig 7d Fig 7 3 The UNIT is shipped with the inlet flange on the right side If needed the orientation can be reversed by following the steps below 1 Loosen SET SCREW 1 with 2...

Страница 6: ...imately 3 seconds 4 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace COVER...

Страница 7: ...or order the complete flush valve assembly from American Standard HOW TO RETROFIT OUR VALVE Fig 10 8 Replaces Industry Standard Manual and Electronic Valves CLEAN CONNECTIONS 2 Fig 10 Fig 10a Fig 10b...

Страница 8: ...ecure the CAP 3 at this time Note You have 5 seconds after connecting cable to enter program code 5 While the SENSOR CONTROL LED 6 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the...

Страница 9: ...FIRST 5 SECONDS NO REPLACE SOLENOID KIT RETRY AUTOMATIC FLUSH WAS IT SUCCESSFUL YES 1 COVER SENSOR FOR 10 SECONDS 2 UNCOVER SENSOR FOR 10 SECONDS REPLACE BATTERY SEE STEP 10 page 6 in manual MANUAL VA...

Страница 10: ...JUSTABLE TAILPIECE M952261 0020A 3 4 INLET PIPE ASSEMBLY M952263 0020A 3 4 VACUUM BREAKER ASSEMBLY M952262 0020A 3 4 SPUD ASSEMBLY SELECTRONIC PROXIMITY URINAL FLUSH VALVE 0 5 1 0 GPF A955058 0020A 3...

Отзывы: