background image

1

2

4

5

6

8

6a

3

CHECK CONNECTIONS FOR LEAKS.

Move HANDLE into "off" position.

Turn on water supplies and check connections for leaks

.

Operate HANDLE up and down, left and right to flush
water lines thoroughly.

Operate HAND SPRAY and check connections for leaks.

CHECK CONNECTIONS

FOR LEAKS

5

SERVICE

6

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

7

If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.

Remove INDEX BUTTON 

(1)

, loosen HANDLE SCREW 

(2)

 and remove HANDLE 

(3)

.

Unthread the ESCUTCHEON CAP 

(4)

. Unthread three MOUNTING SCREWS 

(5)

.

Lift CARTRIDGE 

(6)

 off MANIFOLD 

(7)

 and remove CARTRIDGE SEALS 

(8)

.

Place SEALS 

(8)

 into CARTRIDGE PORTS 

(6a)

.

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

Clean MANIFOLD 

(7)

, CARTRIDGE 

(6)

 ports and SEALS 

(8)

.

Place CARTRIDGE 

(6)

 onto MANIFOLD 

(7)

 and tighten MOUNTING SCREWS 

(5)

 alternately.

 

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

7

M965243 REV. 1.8 (4/19)