HOT
2
M 9 6 5 2 3 8
5
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE
(1)
to remove
HANDLE ASSEMBLY
(2)
from ESCUTCHEON BASE
(3)
.
Use a flat blade screw driver to remove SPRING CLIP
(4)
.
Lift STOP WASHER
(5)
, turn 90˚ and replace.
Replace SPRING CLIP
(4)
.
Reinstall HANDLE ASSEMBLY
(2)
.
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
SERVICE
CARE INSTRUCTIONS:
90˚
16
15
VALVE
13
1
5
3
4
2
CHECK DRAIN CONNECTIONS
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate both HANDLES
(1)
to flush water
lines thoroughly.
Replace AERATOR
(3)
.
1
COLD
2
4
1
“P” TRAP
WASTE
OUTLET
3
Operate POP-UP KNOB
(5)
and fill Sink with water. Check
that DRAIN STOPPER
(4)
makes a good seal and retains
water in Sink. If STOPPER
(4)
does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
Release POP-UP KNOB
(5)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
5
14
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.