background image

2

1

VALVE OUTLET SUPPLY CONNECTION

3

RED BAND

BLUE

BAND

Connect Red Banded Hose to Left Valve and Blue Banded Hose to Right Valve.

Attach COUPLING NUTS 

(1)

 of SUPPLY HOSES 

(2)

 and tighten making water tight connections.

Important: Loop SUPPLY HOSES 

(2)

 as illustrated so they do not kink. 

COLD

HOT

VALVE INSTALLATION

M 9 6 5 2 3 8

MOUNTING
SURFACE

Install LOCKNUT 

(3)

 and RUBBER WASHER 

(4)

 onto VALVE BODY 

(5)

.

From under side of mounting surface, install VALVE BODY 

(5)

 through valve

mounting hole. Threads of VALVE BODY 

(5)

 should extent at least 5/16

of a inch above mounting surface top. 

Fig. A.

 

Thread DECK ADAPTER 

(2)

onto VALVE BODY 

(5)

 until snug against internal stop. If necessary, adjust

LOCKNUT 

(3)

. Tighten LOCKNUT 

(3) 

with WRENCH 

(6)

 supplied.

 

6

2

1

4

3

5

2
1

4

3

Place RUBBER RING 

(1)

 into DECK ADAPTER 

(2)

.

5

5

5/16'' MIN.

Fig.

 

A.

2

4

INSTALL HANDLES

1

2

5

3

TOP

Figure "A"

SPLINE

END UP

Push ADAPTER 

(1)

 on VALVE STEM 

(2).

 See 

Fig. A

. Tighten

STEM SCREW 

(3)

 to secure ADAPTER 

(1)

Find correct position of LEVER HANDLE ASSEMBLY 

(4)

 by adjusting

male teeth on ADAPTER 

(1)

 to female teeth in HANDLE 

(4)

.

Thread LEVER HANDLE ASSEMBLY 

(4)

 onto DECK ADAPTER 

(5)

until snug against mounting surface

.

THREAD ON

TO DECK

ADAPTER

4

Содержание QUENTIN 7440.801

Страница 1: ...cet with MOUNTING NUT 8 pushing faucet to back of sink so SUPPLIES 3 rests against mounting hole Adjust Faucet so that it is centered Tighten MOUNTING NUT 8 to complete faucet mounting INSTALLATION INSTRUCTIONS WIDESPREAD LAVATORY FAUCET with Speed Connect Drain 7440 801 7440 851 QUENTIN To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Co...

Страница 2: ...ads of VALVE BODY 5 should extent at least 5 16 of a inch above mounting surface top Fig A Thread DECK ADAPTER 2 onto VALVE BODY 5 until snug against internal stop If necessary adjust LOCKNUT 3 Tighten LOCKNUT 3 with WRENCH 6 supplied 6 2 1 4 3 5 2 1 4 3 Place RUBBER RING 1 into DECK ADAPTER 2 5 5 5 16 MIN Fig A 2 4 INSTALL HANDLES 1 2 5 3 TOP Figure A SPLINE END UP Push ADAPTER 1 on VALVE STEM 2 ...

Страница 3: ...djustable Wrench or Channel Locks INSTALL DRAIN FROM BELOW FIXTURE 8 From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 4 Fig A Fig B Fig A Fig B POP UP KNOB 1 must be fully ...

Страница 4: ...nd tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B Fig A ATTACH CABLE CONNECTOR 10 2 1 Fig B 1 1 4 O D 4 2 1 3 FERRULE Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bendi...

Страница 5: ...G With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 1 COLD 2 4 1 P TRAP WASTE OUTLET 3 Operate POP UP KNOB 5 and fill Sink with water Check that DRAIN STOPPER 4 makes a good seal and retains water in Sink If STOPPER 4 does not seal properly please refer to Troubleshoo...

Страница 6: ...ow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A Fig F Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where th...

Страница 7: ... the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam in...

Страница 8: ... 0070A CAM SEAT INSERT M913207 0070A TAILPIECE INSERT M952430 0070A CABLE ASSEMBLY M964163 YYY0A SPOUT KIT 7440 851 M964164 YYY0A SPOUT KIT 7440 801 HOT LINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 Weekdays 8 00 a m to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademark...

Отзывы: