Pre-Installation (continued)

WIRING CONNECTION REQUIREMENTS

Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction .
OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNINGS

 

- Electrical grounding is required for this range hood . Check 

with a qualified electrician if you are not sure whether the 

range hood is properly grounded .

 

- Failure to follow electrical requirements may result in a 

fire .

 

- A fuse in the neutral or grounding circuit could result in 

electrical shock .

 

- If the hot/cold water pipe is interrupted by plastic 

nonmetallic gaskets or other materials, DO NOT use for 

grounding .

 

- DO NOT GROUND TO A GAS PIPE .

IMPORTANT: It is the customer’s responsibility to contact a qualified 

electrical installer and assure that the electrical installation is 

adequate and complies with the National Electrical Code, or CSA 

standards, as well as all local codes and ordinances .
1 .  Save installation instructions for electrical inspector’s use .
2 .  If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine if the  

ground path is adequate .

3 .  DO NOT use an extension cord or adapter plug with this  

appliance .

4 .  The range hood must be connected with copper wire only .
5 .  The range hood should be connected directly to the junction 

(or circuit breaker) box through flexible, armoured or 

nonmetallic sheathed copper cable . Allow some slack in the 

cable so the  

appliance can be moved if servicing is ever necessary .

6 .  A UL listed or CSA approved conduit connector must be 

provided at each end of the power supply cable (at the range 

hood and at  

the junction box) .

7 .  When making the electrical connection, cut a 3 .2 cm (1-1/4 in . 

hole in the wall . A hole cut through wood must be sanded until  
smooth . A hole through metal must have a grommet .

8 .  When cutting or drilling into the wall or ceilling, do not damage  

electrical wiring and other hidden utilities .

9 .  Wire size must conform to all local codes and ordinances . 

The latest edition requirements of the National Electrical Code 
ANSI/NFPA 70, or the latest edition CSA Standards C22 .1-94, 
Canadian Electrical Code Part 1 and C22 .2 No . 0-M91 .

DANGER: 

Risk of electrical shock . This range hood 

must be properly grounded .

DANGER: 

Turn off the power circuit breaker or the 

power switch on the junction box before installing this 
unit . Touching circuitry inside the range hood while it is 
energized will result in death or serious injury .

DANGER: 

All electrical wiring must be properly installed, 

insulated, and grounded . Improper insulation and grounding 
will result in deadly electrical shock .

NOTE: 

Temporarily wire the range hood to test it for 

proper operation . If the range hood does not operate 
correctly, do not proceed with the installation .

 

- Cut a 1 1/4 in . (31 .75 ) diameter hole in an appropriate 

location in the wall for the electrical connection . A hole cut 
through wood must be sanded until smooth . A hole through 
metal must have a grommet .

 

- Connect the range hood (A) directly to the junction box or 

circuit breaker box with a flexible, armoured, or nonmetallic 
sheathed copper cable . Allow some slack in the cable so 
the appliance can be moved if servicing is ever necessary . 

 

- Connect a UL-listed or CSA-approved conduit connector to 

each end of the power supply cable (at the range hood and 
at the junction box) . 

 

- Connect the three colored wires (6) from the range  

hood (A) to the corresponding wires (7) from the electrical 
source: black to black (live), white to white (neutral), 
and green to green/yellow (ground) . Cap wires with wire 
connectors .

 

- Turn the power on, and ensure that all lights and fans are 

operating correctly .

 

- Once you have tested the electrical connection, disconnect 

the power supply cable and wires from the electrical 

source before proceeding with the rest of the installation .

7

6

A

Содержание QR031

Страница 1: ...d the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Stainless Steel Chimney Range Hood THANK...

Страница 2: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code auth...

Страница 3: ...rn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan Do not use water including wet dishcloths or towels as you could cause a ste...

Страница 4: ...rred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the respons...

Страница 5: ...knife Marker or pencil Duct tape Adjustable wrench Phillips screwdriver Flathead screwdriver Electric drill or powered screwdriver Safety goggles Safety gloves HARDWARE INCLUDED NOTE Hardware not show...

Страница 6: ...nued PACKAGE CONTENTS B C D E Part Description Quantity A Range hood including pre installed controls lights blower baffle filters and damper 1 B Lower chimney 1 C Upper chimney 1 D Hood bracket 2 E C...

Страница 7: ...from the cooking surface to the range hood is 18 in 458 mm for electric ranges and 29 5 in 750 mm for gas ranges If your gas range specifies a different distance use the greater distance of the two T...

Страница 8: ...with elbows and transitions will reduce the performance of the range hood Use as few of them as possible Use round metal duct work with a uniform diameter of 6 in 152 mm Larger ducting may be require...

Страница 9: ...wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden utilities 9 Wire size mu...

Страница 10: ...e holes in the bracket E Place the hood brackets D on the wall aligning their center notches 11 2 in 284 mm above the horizontal line 2 and 5 36 in 136 mm apart Mark the wall at the center of the hole...

Страница 11: ...d re install it if necessary Insert one end of the damper 3 into the hinge slot 4 at the top of the range hood A Gently bend the damper 3 and insert its other end into the hinge slot 4 5 Installing th...

Страница 12: ...chimney extensions B C and place them on the floor Lower the upper chimney C onto the lower chimney B You should now have both chimney extensions together as one unit Place the chimney onto the range...

Страница 13: ...ing down Once the countdown is completed the range hood will beep the fan and lights will turn off automatically and the clock will show in the screen During the countdown operation You will still be...

Страница 14: ...them with similar baffle filters with stainless steel clips Also replace damaged baffle filters with punctures bends or broken frames Turn off the range hood and disconnect the power Replace with an e...

Страница 15: ...teriorate the surface rapidly Do not allow cleaning compounds salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow deposits to remai...

Страница 16: ...g The thermal protection system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after a...

Страница 17: ...ey 8 74 in W x 8 82 in D x 24 02 in H 222 mm W x 224 mm D x 610 mm H Upper Chimney 8 66 in W x 8 74 in D x 24 02 in H 220 mm W x 222 mm D x 610 mm H WIRING DIAGRAM 29 5 in 750 mm 8 7 in 222 mm 8 7 in...

Страница 18: ...art s and have the part description s ready C D E F A B G AA BB CC Part Description Code Quantity Part Description Code Quantity A Control board QHR142 1 AA Toggle bolt QHR133 4 B Control panel QHR143...

Страница 19: ...Questions problems missing parts Before returning to the store call Customer Service 8 30 a m 5 p m EST Monday Friday 1 877 333 0098 CONGLOM COM Retain this manual for future use...