![American Standard QR031 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/american-standard/qr031/qr031_owners-manual_2929927011.webp)
11 CONGLOM .COM
Please contact 1-877-333-0098 for further assistance .
Installation (continued)
4
Installing the damper (if necessary)
WARNING:
Sharp edges . Wear safety gloves .
CAUTION:
Be very careful when installing the damper .
Applying too much force or bending the damper too much
may damage or break the damper hinge ends .
The damper is pre-installed at the factory . Make sure that it has
not come loose during shipping and re-install it, if necessary .
- Insert one end of the damper (3) into the hinge slot (4) at
the top of the range hood (A) .
- Gently bend the damper (3) and insert its other end into the
hinge slot (4) .
5
Installing the range hood
CAUTION:
Make sure the range hood is secure before
releasing it .
- Lift the range hood (A) into position, engaging the two hood
brackets (D) with the two lower toggle bolts (DD) .
6
Attaching the duct
- Attach your ducting (5) (not supplied) to the range hood (A)
and connect the duct to your exterior exhaust system .
2
1
0.8 in. (20 mm)
11.2 in.
(284 mm)
5.36 in. (136 mm)
18–29.5 in.
(458–750 mm)
Ceiling
D
E
Wall
DD
0.25 in
(6.4 mm)