background image

CHECK CONNECTIONS FOR LEAKS.

Move HANDLE  into "off" position.
Turn on water supplies and check connections for leaks

.

Operate HANDLE 

(2)

 up and down, left and right to flush

water lines thoroughly.
Operate HAND SPRAY and check connections for leaks.

CHECK CONNECTIONS

FOR LEAKS

5

SERVICE

6

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

7

If faucet drips, operate HANDLE several times from "off" to "on." Do not

apply excessive force.

Remove INDEX BUTTON 

(1)

, loosen HANDLE SCREW 

(2)

 and remove HANDLE 

(3)

.

Unthread the ESCUTCHEON CAP 

(4)

. Unthread three MOUNTING SCREWS 

(5)

.

Lift CARTRIDGE 

(6)

 off MANIFOLD 

(7)

.

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

Clean MANIFOLD 

(7)

 and CARTRIDGE 

(6)

 ports.

Place CARTRIDGE 

(6)

 onto MANIFOLD 

(7)

 and tighten MOUNTING SCREWS 

(5)

 alternately.

 

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M 9 6 5 4 5 5   Rev.  1. 2

1

2

4

3

5

6

7

Содержание PORTSMOUTH 4285.410

Страница 1: ...illips Screwdriver RECOMMENDED TOOLS Regular Screwdriver Insert HOSES 2 through RUBBER WASHER 4 BRASS WASHER 5 and threaded LOCKNUT 6 Turn off water at main supply CAUTION PORTSMOUTH M965455 Rev 1 2 B A SINK OR MOUNTING SURFACE 4 5 8 7 6 A Installation with ESCUTCHEON 1 Apply a bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE 1 Make certain the SEAL 9 is properly seated in recess of fau...

Страница 2: ...ons for leaks See Section 5 Turn off hot and cold water supplies before beginning Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left supply Marked with a Red Stripe to Hot and right supply Marked with Blue Stripe to Cold wall supply Use adjustable wrench to tighten connections Do not over tighten Faucet supplies are 21 long from ...

Страница 3: ... off to on Do not apply excessive force Remove INDEX BUTTON 1 loosen HANDLE SCREW 2 and remove HANDLE 3 Unthread the ESCUTCHEON CAP 4 Unthread three MOUNTING SCREWS 5 Lift CARTRIDGE 6 off MANIFOLD 7 Replace ESCUTCHEON CAP 4 HANDLE 3 tighten HANDLE SCREW 1 and install INDEX BUTTON 2 Clean MANIFOLD 7 and CARTRIDGE 6 ports Place CARTRIDGE 6 onto MANIFOLD 7 and tighten MOUNTING SCREWS 5 alternately CA...

Страница 4: ...69 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST IN MEXICO 01 800 839 1200 P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c A S A m e r i c a I n c 2 0 1 2 HOT LINE FOR HELP M964396 YYY0A HANDLE KIT M964397 0070A BUTTON AND SCREW KIT M907315 YYY0A ESCUTCHEON CAP M951483 0070A CARTRIDGE M918511 0070A CARTRIDGE SCREWS PORT...

Отзывы: