M 9 6 8 0 2 6
3
3
4
TEMPERATURE ADJUSTMENT
SET HOT LIMIT STOP
Check that arrow marking B points to the 12 o'clock position. If not, push the BLACK CLAMP on the SECURING RING to
the right, pull off KNOB MOUNT
(3)
and reinstall KNOB MOUNT
(3)
with arrow
"B"
12 o'clock position.
See Figure 1.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT
(3)
until the spout temperature is 100˚F. Check
that arrow
"A"
on the KNOB MOUNT
(3)
still points 12 o'clock position after adjusting the thermostat to 100˚F.
If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT
(3)
by pulling it towards you while standing directly in
front of the valve.
Reinstall the KNOB MOUNT
(3)
with arrow
"A"
12 o'clock position.
The maximum mixed water temperature is set at 109˚F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP
(H shaped Black Plastic part)
. Reinstall it at the desired notch as indicated in
the diagram to limit the maximum mixed water temperature to 104˚F or 112˚F.
Reinstall RED LOCKING DEVICE.
See
Step 2
for HANDLE
(2)
installation.
Loosen SET SCREW
(1)
. Pull off HANDLE ASSEMBLY
(2)
.
ARROW
"A"
BLACK
CLAMP
ARROW
"B"
RED LOCKING
DEVICE
TEMPERATURE
LIMIT STOP
ARROWS AT 12 O'CLOCK
POSITION
Figure 1
KNOB MOUNT
112
109
104
1
2